ONS SDH TL1 Command Guide R8.5.1 -- Conditions
From DocWiki
This chapter lists the conditions for TL1 commands and autonomous messages for the Cisco ONS 15454 SDH and Cisco ONS 15600 SDH Release 8.5. These conditions are listed in Table 26-1.
Conditions include any problem detected on an ONS 15454 SDH and ONS 15600 SDH shelf. They can include standing or transient notifications. A snapshot of all current raised, standing conditions on the network, node, or card can be retrieved in the Cisco Transport Controller (CTC) Conditions window or using the RTRV-COND commands. (In addition, some but not all cleared conditions are also found in the History tab in CTC.)
Table 26-1: Conditions
| Condition | Description |
|---|---|
|
AIS |
Alarm Indication Signal |
|
AIS-L |
Alarm Indication Signal-Line |
|
ALS |
Automatic Laser Shutdown |
|
AMPLI-INIT |
Optical Amplifier Initialization |
|
APC-DISABLED |
Automatic Power Control Disabled |
|
APC-FAIL |
Automatic Power Control Failure |
|
APSB |
Byte Failure |
|
APSC-IMP |
Improper Automatic Protection Switch (APS) Code |
|
APSCDFLTK |
Default K Byte |
|
APSCINCON |
Inconsistent APS Code |
|
APSCM |
Protection Switching Channel Match Failure |
|
APSCNMIS |
Node ID Mismatch |
|
APSIMP |
APS Invalid Mode |
|
APSMM |
APS Mode Mismatch |
|
AS-CMD |
Alarms Suppressed By User Command |
|
AS-MT |
Alarms Suppressed For Maintenance |
|
AU-AIS |
AIS-Administration Unit-Alarm Indication Signal |
|
AU-LOF |
LOF-Administration Unit-Loss of Multi Frame |
|
AU-LOP |
LOP-Administration Unit-Loss of Pointer |
|
AUD-LOG-LOSS |
Audit Log 100 Percent Full-Oldest records will be lost |
|
AUD-LOG-LOW |
Audit Log 80 Percent Full |
|
AUTOLSROFF |
Automatic Laser Shutoff Due To High Temperature |
|
AUTORESET |
Automatic System Reset |
|
AUTOSW-AIS-SNCP |
Automatic SNCP Switch caused by AIS |
|
AUTOSW-LOP-SNCP |
Automatic SNCP Switch Caused By LOP |
|
AUTOSW-PDI-SNCP |
Automatic SNCP Switch Caused By PDI |
|
AUTOSW-SDBER-SNCP |
Automatic SNCP Switch Caused By SDBER |
|
AUTOSW-SFBER-SNCP |
Automatic SNCP Switch Caused By SFBER |
|
AUTOSW-UNEQ-SNCP |
Automatic SNCP Switch Caused By UNEQ |
|
AWG-DEG |
AWG Temperature Degrade |
|
AWG-FAIL |
AWG Temperature Failure |
|
AWG-OVERTEMP |
AWG Over-Temperature |
|
AWG-WARM-UP |
AWG Warm Up |
|
BAT-FAIL |
Battery Failure |
|
BAT-HGH-VLT |
High Volt |
|
BAT-LOW-VLT |
Low Volt |
|
BKUPMEMP |
Primary Non-Volatile Backup Memory Failure |
|
CARLOSS |
Carrier Loss On The LAN |
|
CASETEMP-DEG |
Case Temperature Degrade |
|
CKTDOWN |
Signaling unable to set up circuit |
|
CLDRESTART |
Cold Restart |
|
COMIOXC |
IO Slot To XCON Communication Failure |
|
COMM-FAIL |
Plug-in Module Communication Failure |
|
CONTBUS-A-18 |
TCC A To DCC A Processor Communication Failure |
|
CONTBUS-B-18 |
TCC B To DCC B Processor Communication Failure |
|
CONTBUS_A |
Controller A To Shelf Slot Communication Failure |
|
CONTBUS_B |
Controller B To Shelf Slot Communication Failure |
|
CTNEQPT-MISMATCH |
Connection Equipment Mismatch |
|
CTNEQPT-PBPROT |
Interconnection Equipment Failure-Protect XC Payload Bus |
|
CTNEQPT-PBWORK |
Interconnection Equipment Failure-Working XC Payload Bus |
|
DATAFLT |
Software Fault-Data Integrity Fault |
|
DBOSYNC |
Standby Database Out of Sync |
|
DS3-MISM |
DS3 Frame Format Mismatch |
|
DSP-COMM-FAIL |
DSP Communication Failure |
|
DSP-FAIL |
DSP Failure |
|
DUP-IPADDR |
IP address already in use within the same DCC Area |
|
DUP-NODENAME |
Node name already in use within the same DCC area |
|
E-W-MISMATCH |
Both Ends Of Fiber Provisioned As East Or Both As West |
|
E3-ISD |
E3 Idle Condition |
|
EHIBATVG |
Extreme High Volt |
|
ELWBATVG |
Extreme Low Volt |
|
EOC |
RS-DCC Termination Failure |
|
EQPT |
Equipment Failure |
|
EQPT-MISS |
Replaceable Equipment/Unit is Missing |
|
ERFI-P-CONN |
Enhanced Remote Failure Indication-Path-Connectivity |
|
ERFI-P-PAYLD |
Enhanced Remote Failure Indication-Path-Payload |
|
ERFI-P-SRVR |
Enhanced Remote Failure Indication-Path-Server |
|
ERROR-CONFIG |
Error in Startup Configuration |
|
ETH-LINKLOSS |
Rear Panel Ethernet Link Removed |
|
EXCCOL |
Excess Collisions On The LAN |
|
EXERCISE-RING-FAIL |
Exercise Request on Ring Failed |
|
EXERCISE-RING-REQ |
Exercise Request on Ring |
|
EXERCISE-SPAN-FAIL |
Exercise Request on Span Failed |
|
EXERCISE-SPAN-REQ |
Exercise Request on Span |
|
EXT |
Failure Detected External To The NE |
|
EXTRA-TRAF-PREEMPT |
Extra Traffic Preempted |
|
FAILTOSW |
Failure To Switch To Protection |
|
FAILTOSW-HO |
Failure To Switch To Protection-High Order Path |
|
FAILTOSW-LO |
Failure To Switch To Protection-Low Order Path |
|
FAILTOSWR |
Failure To Switch To Protection-Ring |
|
FAILTOSWS |
Failure To Switch To Protection-Span |
|
FAN |
Fan Failure |
|
FANDEGRADE |
Partial Fan Failure |
|
FE-AIS |
Far End AIS |
|
FE-DS1-MULTLOS |
Far End Multiple DS1 LOS Detected On DS3 |
|
FE-DS1-NSA |
Far End DS1 Equipment Failure-Non Service Affecting |
|
FE-DS1-SA |
Far End DS1 Equipment Failure-Service Affecting |
|
FE-DS1-SNGLLOS |
Far End Single DS1 LOS |
|
FE-DS3-NSA |
Far End DS3 Equipment Failure-Non Service Affecting |
|
FE-DS3-SA |
Far End DS3 Equipment Failure-Service Affecting |
|
FE-E1-MULTLOS |
Far end multiple E1 LOS detected on E3 |
|
FE-E1-NSA |
Far end E1 eqpt fail non service affecting |
|
FE-E1-SA |
Far end E1 eqpt fail service affecting |
|
FE-E1-SNGLLOS |
Far end signal E1 LOS |
|
FE-E3-NSA |
Far end E3 eqpt fail non service affecting |
|
FE-E3-SA |
Far end E3 eqpt fail service affecting |
|
FE-EQPT-NSA |
Far End Common Equipment Failure-Non Service Affecting |
|
FE-EXERCISING-RING |
Far End Exercising Ring |
|
FE-EXERCISING-SPAN |
Far End Exercising Span |
|
FE-FRCDWKSWPR-RING |
Far End Working Facility Forced To Switch To Protection-Ring |
|
FE-FRCDWKSWPR-SPAN |
Far End Working Facility Forced To Switch To Protection-Span |
|
FE-IDLE |
Far End IDLE |
|
FE-LOCKOUTOFPR-ALL |
Far End Lockout Of Protection-All Spans |
|
FE-LOCKOUTOFPR-RING |
Far End Lockout Of Protection-Ring |
|
FE-LOCKOUTOFPR-SPAN |
Far End Lockout Of Protection-Span |
|
FE-LOCKOUTOFWK-RING |
Far End Lockout Of Working-Ring |
|
FE-LOCKOUTOFWK-SPAN |
Far End Lockout Of Working-Span |
|
FE-LOF |
Far End LOF |
|
FE-LOS |
Far End LOS |
|
FE-MANWKSWPR-RING |
Far End Manual Switch Of Working Facility To Protection-Ring |
|
FE-MANWKSWPR-SPAN |
Far End Manual Switch Of Working Facility To Protection-Span |
|
FE-SDPRLF |
APS Channel-Far End Protection Line Signal Degrade |
|
FEC-MISM |
FEC Mismatch |
|
FEPRLF |
Far End Protection Line Failure |
|
FIBERTEMP-DEG |
Fiber Temperature Degrade |
|
FORCED-REQ |
Forced Switch Request |
|
FORCED-REQ-RING |
Forced Switch Request On Ring |
|
FORCED-REQ-SPAN |
Forced Switch Request On Span |
|
FRCDSWTOINT |
Forced Switch To Internal Clock |
|
FRCDSWTOPRI |
Forced Switch To Primary Reference |
|
FRCDSWTOSEC |
Forced Switch To Second Reference |
|
FRCDSWTOTHIRD |
Forced Switch To Third Reference |
|
FRNGSYNC |
Free Running Synchronization Mode |
|
FSTSYNC |
Fast Start Synchronization Mode |
|
FULLPASSTHR-BI |
Bidirectional Full Pass Through Is Active |
|
GAIN-HDEG |
Optical Amplifier Gain Degrade High |
|
GAIN-HFAIL |
Optical Amplifier Gain Failure High |
|
GAIN-LDEG |
Optical Amplifier Gain Degrade Low |
|
GAIN-LFAIL |
Optical Amplifier Gain Failure Low |
|
GCC-EOC |
GCC Termination Failure |
|
GE-OOSYNC |
Gigabit Ethernet Out of Sync |
|
HI-LASERBIAS |
Equipment High Laser Bias |
|
HI-RXPOWER |
Equipment High Receive Power |
|
HI-TXPOWER |
Equipment High Transmit Power |
|
HITEMP |
High Temperature |
|
HLDOVRSYNC |
Holdover Synchronization Mode |
|
HP-RFI |
Remote Failure Indication-High Order-Remote Failure/Alarm Indication |
|
HP-TIM |
High Order-Trace Identifier Mismatch Failure |
|
HP-UNEQ |
Signal Label Mismatch Failure (SLMF)-Unequipped High Order-Path Unequipped |
|
I-HITEMP |
Industrial High Temperature |
|
IMPROPRMVL |
Improper Removal |
|
INC-GFP-OUTOFFRAME |
Out Of Frame Detected by Generic Framing Protocol (GFP) Receiver |
|
INC-GFP-SIGLOSS |
Client Signal Loss Frames Detected by GFP Receiver |
|
INC-ISD |
DS3 Idle Condition |
|
INC-SIGLOSS |
Incoming Signal Loss on Fibre Channel Interface |
|
INC-SYNCLOSS |
Incoming Synchronization Loss on Fibre Channel Interface |
|
INC_GFP_SYNCLOSS |
Client Synchronization Loss Frames Detected by GFP Receiver |
|
INHSWPR |
Inhibit Switch To Protect Request On Equipment |
|
INHSWWKG |
Inhibit Switch To Working Request On Equipment |
|
INTRUSION-PSWD |
Security Intrusion Attempt Detected-See Audit Log |
|
INVMACADR |
Invalid MAC Address |
|
IOSCFGCOPY |
Ios Config Copy In Progress |
|
KB-PASSTHR |
K Bytes Pass-Through Is Active |
|
KBYTE-APS-CHANNEL-FAILURE |
Kbyte Channel Failure |
|
LAN-POL-REV |
Lan Connection Polarity Reversed |
|
LASER-APR |
Laser Auto Power Reduction |
|
LASERBIAS-DEG |
Laser Bias Degrade |
|
LASERBIAS-FAIL |
Laser Bias Failure |
|
LASEREOL |
Laser Approaching End of Life |
|
LASERTEMP-DEG |
Laser Temperature Degrade |
|
LKOUTPR-R |
Lockout Of Protection-Ring |
|
LKOUTPR-S |
Lockout Of Protection-Span |
|
LKOUTWK-R |
Lockout Of Working-Ring |
|
LKOUTWK-S |
Lockout Of Working-Span |
|
LMP-HELLODOWN |
Link Management Protocol (LMP) Hello FSM to Control Channel down |
|
LMP-NDFAIL |
LMP Neighbor Discovery has failed |
|
LO-RXPOWER |
Equipment Low Receive Power |
|
LO-TXPOWER |
Equipment Low Transmit Power |
|
LOA |
Loss of Alignment |
|
LOC |
Loss of Channel |
|
LOCKOUT-REQ |
Lockout Switch Request On Facility or Equipment |
|
LOCKOUT-REQ-RING |
Lockout Switch Request On Ring |
|
LOCKOUTOFPR |
Lockout Of Protection |
|
LOF |
Loss Of Frame |
|
LOM |
Loss of Multi-Frame |
|
LOS |
Loss Of Signal |
|
LOS-CONT |
Loss Of Continuity |
|
LP-PLM |
Signal Label Mismatch Failure (SLMF)-PLM Low Order-Path Label Mismatch |
|
LP-RFI |
RFI-Low Order-Remote Failure/Alarm Indication |
|
LP-TIM |
TIM Low Order-Trace Identifier Mismatch Failure |
|
LP-UNEQ |
Signal Label Mismatch Failure (SLMF)-Unequipped Low Order-Path Unequipped |
|
LPBKCRS |
Cross-connect Loopback |
|
LPBKDS1FEAC |
DS1 Loopback Due To Far End Alarm and Control (FEAC) Command |
|
LPBKDS3FEAC |
DS3 Loopback Due To FEAC Command |
|
LPBKDS3FEAC-CMD |
DS3 Loopback Command Sent To Far End |
|
LPBKE1FEAC |
E1 loopback due to FEAC command |
|
LPBKE3FEAC |
E3 loopback due to FEAC command |
|
LPBKE3FEAC-CMD |
E3 loopback command sent to far end |
|
LPBKFACILITY |
Facility Loopback |
|
LPBKTERMINAL |
Terminal Loopback |
|
MAN-REQ |
Manual Switch Request |
|
MANRESET |
Manual System Reset |
|
MANSWTOINT |
Manual Switch To Internal Clock |
|
MANSWTOPRI |
Manual Switch To Primary Reference |
|
MANSWTOSEC |
Manual Switch To Second Reference |
|
MANSWTOTHIRD |
Manual Switch To Third Reference |
|
MANUAL-REQ-RING |
Manual Switch Request On Ring |
|
MANUAL-REQ-SPAN |
Manual Switch Request On Span |
|
MEA |
Mismatch Of Equipment And Attributes |
|
MEM-GONE |
Free Memory On Card Near Zero |
|
MEM-LOW |
Free Memory On Card Very Low |
|
MFGMEM |
Manufacturing Data Memory (EEPROM Failure) |
|
MS-AIS |
AIS-Multiplex Section-Alarm Indication Signal |
|
MS-EOC |
Multiplex Section DCC Termination Failure |
|
MS-RFI |
RFI-Multiplex Section-Remote Failure/Alarm Indication |
|
MSSP-OOSYNC |
Procedural Error-MS-SPRing out of sync |
|
NO-CONFIG |
No Startup Configuration |
|
NTWTPINC |
Network Topology Incomplete |
|
OCHNC-ACTIV-FAIL |
Optical Channel Activation Failure |
|
OCHNC-DEACTIV-FAIL |
Optical Channel Deactivation Failure |
|
OCHNC-FAIL |
Optical Channel Connection Failure |
|
OCHNC-INC |
Optical Channel Incomplete |
|
ODUK-AIS-PM |
ODUk: Alarm Indication Signal |
|
ODUK-BDI-PM |
ODUk: PM Backward Defect Indication |
|
ODUK-LCK-PM |
ODUk: Locked Defect -Performance Monitoring (PM) |
|
ODUK-OCI-PM |
ODUk: Open Connection Indication |
|
ODUK-SD-PM |
ODUk: Signal Degrade |
|
ODUK-SF-PM |
ODUk: Signal Failure |
|
ODUK-TIM-PM |
ODUk: Trail Trace Identifier Mismatch |
|
OOU-TPT |
Out of Use-Transport Failure |
|
OPTNTWMIS |
Optical Network Type Mismatch |
|
OPWR-HDEG |
Optical Power Degrade High |
|
OPWR-HFAIL |
Optical Power Failure High |
|
OPWR-LDEG |
Optical Power Degrade Low |
|
OPWR-LFAIL |
Optical Power Failure Low |
|
OTUK-AIS |
OTUk: Alarm Indication Signal |
|
OTUK-BDI |
OTUk: Backward Defect Indication |
|
OTUK-LOF |
OTUk: Loss Of Frame |
|
OTUK-SD |
OTUk: Signal Degrade |
|
OTUK-SF |
OTUk: Signal Failure |
|
OTUK-TIM |
OTUk: Trail Trace Identifier Mismatch |
|
OUT-OF-SYNC |
8B10B Out of Sync |
|
PDI-P |
Payload Defect Indication-Path |
|
PEER-NORESPONSE |
Peer Card Not Responding |
|
PORT-CODE-MISM |
Pluggable port security code mismatch |
|
PORT-COMM-FAIL |
Module Communication Failure |
|
PORT-MISMATCH |
Pluggable port rate mismatch |
|
PORT-MISSING |
Pluggable port missing |
|
PRC-DUPID |
Duplicate Node ID |
|
PROTNA |
Protection Unit Not Available |
|
PTIM |
Payload Type Identifier Mismatch |
|
PWR-REDUN |
Redundant Power Capability Lost |
|
RAI |
Remote Alarm Indication |
|
RCVR-MISS |
Facility Termination Equipment-Receiver Missing |
|
RFI |
Remote Failure Indication |
|
RFI-L |
Remote Failure Indication-Line |
|
RING-ID-MIS |
Ring Id Mismatch |
|
RING-MISMATCH |
Far End Of Fiber Is Provisioned With Different Ring ID |
|
RING-SW-EAST |
Ring Switch Is Active On The East Side |
|
RING-SW-WEST |
Ring Switch Is Active On The West Side |
|
RSVP-HELLODOWN |
RSVP Hello FSM to Neighbor down |
|
RUNCFG-SAVENEED |
Need to Save Running Config |
|
SD |
Signal Degrade |
|
SD-L |
Bit Error Rate (BER) Threshold Exceeded For Signal Degrade-Line |
|
SDBER-EXCEED-HO |
BER Threshold Exceeded For Signal Degrade-High Order |
|
SF |
Signal Failure |
|
SF-L |
BER Threshold Exceeded For Signal Failure-Line |
|
SFBER-EXCEED-HO |
BER Threshold Exceeded For Signal Failure-High Order |
|
SFTWDOWN |
Software Download In Progress |
|
SH-INS-LOSS-VAR-DEG-HIGH |
Shutter Insertion Loss Variation Degrade High |
|
SH-INS-LOSS-VAR-DEG-LOW |
Shutter Insertion Loss Variation Degrade Low |
|
SHUTTER-OPEN |
Shutter Open |
|
SNTP-HOST |
Simple Network time Protocol (SNTP) Host Failure |
|
SPAN-SW-EAST |
Span Switch Is Active On The East Side |
|
SPAN-SW-WEST |
Span Switch Is Active On The West Side |
|
SQM |
Sequence Mismatch |
|
SQUELCH |
Ring Is Squelching Traffic |
|
SQUELCH-PATH |
Squelching Path |
|
SQUELCHED |
Equipment Squelched |
|
SSM-DUS |
Do Not Use For Synchronization |
|
SSM-FAIL |
Failed To Receive Synchronization Status Message |
|
SSM-LNC |
ITU-T G.812-Local Node Clock traceable |
|
SSM-OFF |
Synchronization Status Messages Are Disabled On This Interface |
|
SSM-PRC |
ITU-T G.811-Primary Reference Clock traceable |
|
SSM-PRS |
Stratum 1 Primary Reference Source Traceable |
|
SSM-RES |
Reserved For Network Synchronization Use |
|
SSM-SDH-TN |
ITU-T G.812-Transit Node Clock traceable |
|
SSM-SETS |
ITU-T G.813-Synchronous Equipment Timing Source traceable |
|
SSM-SMC |
SDH Minimum Clock Traceable |
|
SSM-ST2 |
Stratum 2 Traceable |
|
SSM-ST3 |
Stratum 3 Traceable |
|
SSM-ST3E |
Stratum 3E Traceable |
|
SSM-ST4 |
Stratum 4 Traceable |
|
SSM-STU |
Synchronized-Traceability Unknown |
|
SSM-TNC |
Transit Node Clock Traceable |
|
SWMTXMOD |
Switching Matrix Module Failure |
|
SWTOPRI |
Switch To Primary Reference |
|
SWTOSEC |
Switch To Second Reference |
|
SWTOTHIRD |
Switch To Third Reference |
|
SYNC-FREQ |
Synchronization Reference Frequency Out Of Bounds |
|
SYNCPRI |
Primary Synchronization Reference Failure |
|
SYNCSEC |
Secondary Synchronization Reference Failure |
|
SYNCTHIRD |
Third Synchronization Reference Failure |
|
SYSBOOT |
System Reboot |
|
TIM |
TIM Section-Trace Identifier Mismatch Failure |
|
TIM-MON |
TIM Section Monitor-Trace Identifier Mismatch Failure |
|
TPTFAIL |
Transport layer failure |
|
TRMT |
Transmit Failure |
|
TRMT-MISS |
Facility Termination Equipment-Transmitter Missing |
|
TU-AIS |
AIS-Tributary Unit-Alarm Indication Signal |
|
TU-LOP |
LOP-Tributary Unit-Loss of Pointer |
|
TUNDERRUN |
Ethernet Transmit First In First Out Underrun |
|
TX-AIS |
Alarm Indication Signal in TX |
|
TX-RAI |
Remote Alarm Indication in TX |
|
UNC-WORD |
FEC Uncorrected Word |
|
VCG-DEG |
VCAT Group Degraded |
|
VCG-DOWN |
VCAT Group Down |
|
VOA-HDEG |
Variable Optical Attenuator Degrade High |
|
VOA-HFAIL |
Variable Optical Attenuator Failure High |
|
VOA-LDEG |
Variable Optical Attenuator Degrade Low |
|
VOA-LFAIL |
Variable Optical Attenuator Failure Low |
|
WKSWPR |
Switched To Protection |
|
WTR |
Wait To Restore |
|
WVL-MISMATCH |
Equipment Wavelength Mismatch |