H.323 Troubleshooting: H.323 Service Must be Registered with Gatekeeper to Perform IP Transfers Error
From DocWiki
H.323 Service Must be Registered with Gatekeeper to Perform IP Transfers Error
| Problem Summary | Error message in the H.323 Service logs states “ERROR: H.323 Service must be registered with Gatekeeper to perform IP transfers” during a call. |
| Error Message | H.323 Service must be registered with Gatekeeper to perform IP transfers. |
| Possible Cause | The Unified CVP Call Server is not successfully registered with the H.323 Gatekeeper. |
| Recommended Action | Set the Gatekeeper IP address from the VBAdmin using setGK <Gatekeeper IP address>. Restart the Unified CVP Call Server after changing the H.323 Gatekeeper. |
| Release | Release 7.0(2) |
| Associated CDETS # | None. |