Problem Summary In system inventory we don’t see two entries for each VVB configured in the system.
Error Message Missing CVVB product type entries in “App Server Information”.
Possible Cause The configuration imported had CVVB configured on 11.0 this resulted to one entry. This is a migration issue from CVVB 11.0 to 11.5.
Recommended Action Delete and add the Voice Browsers again, this will list two entries as expected (Product type CVVB and VGW) for each instance of Voice Browser.