Cisco Unified MeetingPlace, Release 7.0 -- Setting Chassis Temperature Thresholds for the Media Server

From DocWiki

Jump to: navigation, search

Main page: Cisco Unified MeetingPlace, Release 7.0



Procedure
  1. Access the MSA interface of the module installed in the top slot of the chassis. See Accessing the MSA Interface.
  2. Click System on the sidebar.
  3. Enter a Celsius value in the High field for the critical temperature threshold.
    Tip: We recommend that you set the critical threshold to 40 degrees Celsius.
    The alarm and temperature LEDs both light red when the operating temperature inside the chassis rises above this value.
  4. Enter a Celsius value in the Low field for the safe temperature threshold.
    Tip: We recommend that you set the safe threshold to 35 degrees Celsius.
    The alarm and temperature LEDs both light green when the operating temperature inside the chassis falls below this value.
    The alarm and temperature LEDs both light red when the difference between the temperatures recorded by the high and low sensors is greater than five degrees Celsius, and both temperatures are above the value set in the High field.
    The alarm and temperature LEDs both blink green when the difference between the temperatures recorded by the High and Low sensors is greater than five degrees Celsius, and at least one of the temperatures is below the value set in the High field.
  5. Click Upload to save your changes.
  6. Click Refresh to refresh the MSA system section.

Rating: 0.0/5 (0 votes cast)

Personal tools