You place a test call and immediately receive a busy signal

From DocWiki

Revision as of 13:54, 12 September 2012 by Tataj (Talk)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search
Problem Summary

You place a test call and immediately receive a busy signal

Error Message

NA

Possible Cause

NA

Recommended Action

Check the following:

  • Try pinging or Telnet to the voice gateway to be sure it is up.
  • Use dir to examine the files on the gateway and be sure you transferred:CVPSelfService.tcl
    Refer to Transfer Bootstrap and .WAV Files to the Gateway.
  • A busy signal is the response on a POTS phone if you dial a number that is not configured in the exercise.
Release

NA

Associated CDETS #

None.

Back: Troubleshooting Tips for Getting Started with CVP

Rating: 0.0/5 (0 votes cast)

Personal tools