Problem Summary

You place a test call and immediately receive a busy signal

Error Message

NA

Possible Cause

NA

Recommended Action

Check the following:

  • Try pinging or Telnet to the voice gateway to be sure it is up.
  • Use dir to examine the files on the gateway and be sure you transferred:CVPSelfService.tcl
    Refer to Transfer Bootstrap and .WAV Files to the Gateway.
  • A busy signal is the response on a POTS phone if you dial a number that is not configured in the exercise.