Unified ICM and Unified CCE Database Troubleshooting: Router Process Rejects Logger Configuration Data Load
From DocWiki
(Difference between revisions)
(New page: == Router Process Rejects Logger Configuration Data Load == <table border="1"><tr><td> '''Problem Summary''' </td><td>During initialization, the Router process rejects the configuration d...) |
m (1 revision) |
||
| (3 intermediate revisions not shown) | |||
| Line 9: | Line 9: | ||
</td></tr><tr><td> '''Recommended Action''' </td><td>Increase the following registry key value: Router\CurrentVersion\Configuration\Config\LargeTableTimeout | </td></tr><tr><td> '''Recommended Action''' </td><td>Increase the following registry key value: Router\CurrentVersion\Configuration\Config\LargeTableTimeout | ||
| - | </td></tr><tr><td> '''Release''' </td><td>Release 7.5(1)</td></tr><tr><td> '''Associated CDETS #''' </td><td> None. </td></tr></table> | + | </td></tr><tr><td> '''Release''' </td><td>Release 7.5(1) and 8.0</td></tr><tr><td> '''Associated CDETS #''' </td><td> None. </td></tr></table> |
[[Category:Unified ICM/CCE & Hosted, Release 7.5]] | [[Category:Unified ICM/CCE & Hosted, Release 7.5]] | ||
| + | [[Category:Unified CCE, Release 8.0]] | ||
Latest revision as of 23:53, 12 March 2010
Router Process Rejects Logger Configuration Data Load
| Problem Summary | During initialization, the Router process rejects the configuration data load from logger. |
| Error Message | None. |
| Possible Cause | This occurs because the Logger is busy and does not send a heartbeat to the Router. The Router waits for the heartbeat for 2 minutes (the default interval), doesn't receive a heartbeat, and finally rejects the data. |
| Recommended Action | Increase the following registry key value: Router\CurrentVersion\Configuration\Config\LargeTableTimeout |
| Release | Release 7.5(1) and 8.0 |
| Associated CDETS # | None. |