Router Process Rejects Logger Configuration Data Load

Problem Summary During initialization, the Router process rejects the configuration data load from logger.
Error Message None.
Possible Cause This occurs because the Logger is busy and does not send a heartbeat to the Router. The Router waits for the heartbeat for 2 minutes (the default interval), doesn't receive a heartbeat, and finally rejects the data.
Recommended Action Increase the following registry key value: Router\CurrentVersion\Configuration\Config\LargeTableTimeout