Unified ICM and Unified CCE Database Troubleshooting: Router Process Rejects Logger Configuration Data Load
From DocWiki
(Difference between revisions)
(New page: == Router Process Rejects Logger Configuration Data Load == <table border="1"><tr><td> '''Problem Summary''' </td><td>During initialization, the Router process rejects the configuration d...) |
m (1 revision) |
Revision as of 21:40, 1 October 2009
Router Process Rejects Logger Configuration Data Load
| Problem Summary | During initialization, the Router process rejects the configuration data load from logger. |
| Error Message | None. |
| Possible Cause | This occurs because the Logger is busy and does not send a heartbeat to the Router. The Router waits for the heartbeat for 2 minutes (the default interval), doesn't receive a heartbeat, and finally rejects the data. |
| Recommended Action | Increase the following registry key value: Router\CurrentVersion\Configuration\Config\LargeTableTimeout |
| Release | Release 7.5(1) |
| Associated CDETS # | None. |