Unified ICM and Unified CCE Database Troubleshooting: Recovery Process Assert

From DocWiki

Revision as of 21:40, 1 October 2009 by Cchetty (Talk | contribs)
Jump to: navigation, search

Recovery Process Assert

Problem Summary The Recovery process asserts with the following message
Error Message "Fail: Assertion failed: (keytop - keybase) >= 0.0."
Possible Cause The recovery process has written a bad ToRecoveryKey value for a historical table in the Recovery control table. It may happen if the system time has been set back on the Router node. It may also happen if the logger and router on one side of the system start when does not see another side is up and running. It therefore creates its own RecoveryKey instead of synchronize with another side.
Recommended Action Manually remove the out of sequence ToRecoveryKey in the Recovery table on the HDS database.
Release Release 7.5(1)
Associated CDETS # None.