VRU Script Returns Incorrect Result

Problem Summary When prompted, the caller enters digits, but the script returns incorrect results.
Error Message None.
Possible Cause One of the most likely possibilities is that this is a scripting issue. For example, setting user.microapp.play_data = 167.8900, but when the audio is played, customer hears "one hundred sixty seven point eight nine". The "zero zero" from the value of 167.8900 is missing. This is because of missing double quote signs to make the passed data "167.8900" as a string. Without these double quote signs around the value, it is treated as a number instead of a string.
Recommended Action Add the double quote signs around the Micro-Application value.
Release Release 7.0(2)