Silent Monitor: The function only works one way across the VPN tunnel

From DocWiki

(Difference between revisions)
Jump to: navigation, search
(The function only works one way across the VPN tunnel)
m (Bot: Adding {{Template:Required Metadata}})
 
(One intermediate revision not shown)
Line 1: Line 1:
 +
{{Template:Required Metadata}}
== The function only works one way across the VPN tunnel ==
== The function only works one way across the VPN tunnel ==

Latest revision as of 17:53, 18 December 2009

The function only works one way across the VPN tunnel

Problem Summary Silent Monitoring experiences 1 way audio across VPN. As soon as agents go home and connect into the network via Remote Cisco 831 to HQ located Cisco 3845 (acting as VPN Concentrator), the Silent Monitoring function only works one way.
Error Message None.
Possible Cause This issue only occurs when a call goes across the VPN tunnel which activates the Checkpoint software.
Recommended Action Disable the Checkpoint firewall and two way audio can be heard when silent monitoring. This works fine on the LAN, both sides of conversation can be monitored.
Release Release 7.5(x)
Associated CDETS # None.

Rating: 0.0/5 (0 votes cast)