Silent Monitor: Developer Information
From DocWiki
Revision as of 17:53, 18 December 2009 by Docwikibot (Talk | contribs)
Silent Monitor Developer Information
| Problem Summary | This section pertains only to developers creating custom applications using Silent Monitor. The out-of-the-box CTI Toolkit IPCC Supervisor Desktop and CTI Toolkit Agent Desktop install applications perform all required configuration automatically. |
|---|---|
| Error Message | None. |
| Possible Cause | The CTI OS silent monitor feature requires that you modify a WinPcap registry setting after installing (or reinstalling) WinPcap. |
| Recommended Action | For supervisor desktops using silent monitor, you need to install the following files:
For agent desktops using silent monitor you need to run the WinPcap install executable: WinPcap_3_0_nogui.exe In the Windows registry go to the following registry key: HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\NPF Change the value of the Start setting under this key from 0x00000003 to 0x00000002. Reboot the PC. |
| Release | Release 7.5(x) |
| Associated CDETS # | None. |