SNMP-based network management tools cannot monitor Cisco Unified CCX components

From DocWiki

(Difference between revisions)
Jump to: navigation, search
m (1 revision)
m (Bot: Adding {{Template:Required Metadata}})
 
Line 1: Line 1:
 +
{{Template:Required Metadata}}
== SNMP-based network management tools cannot monitor Cisco Unified CCX components ==
== SNMP-based network management tools cannot monitor Cisco Unified CCX components ==

Latest revision as of 18:36, 18 December 2009

SNMP-based network management tools cannot monitor Cisco Unified CCX components

Problem Summary You are unable to monitor Cisco Unified CCX components with SNMP-based network management tools, such as CiscoWorks.
Error Message None.
Possible Cause The SNMP subagents that monitor Cisco Unified CCX components are not loaded or configured properly, or the SNMP service is not running.
Recommended Action

Complete the following steps:

  1. Make sure that each subagent has a key under the following SNMP service registry: HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\SNMP\Parameters\ExtensionAgents
  2. Make sure that the subagent DLL exists under the directory specified in the registry. For example, expect the subagent SnmpSysAppAgent to have a registry under HKEY_LOCAL_MACHINE\SOFTWARE\ Cisco Systems, Inc.\SnmpSysAppAgent\CurrentVersion and a path name that points to the location of the SnmpSysApp subagent SnmpSysAppImpl.dll.
  3. Make sure that the SNMP service is running on the Cisco Unified CCX server. If it is not, start the SNMP service.
Release Release 7.0(1)
Associated CDETS # None.

Rating: 5.0/5 (1 vote cast)