RTMT does not show alarm info if the primary node is out of service
Problem Summary | The Unified Real Time Monitoring Tool (Unified RTMT) is connected to the secondary node, but after logging in to RTMT, alarm information is not shown. Instead, an error is reported. |
---|---|
Error Message | Error polling alert status - AMC service is down |
Possible Cause | By default, the Primary Collector for the Alert Manager and Collector Service (AMC) is configured on the primary node, and the Failover Collector is not active. If the primary node is down, there is no available collector to which RTMT can connect. |
Recommended Action |
|
Release | Release 8.5(1), Release 8.5(2), Release 8.5(3), Release 8.5(4) |