RTMT: Unified RTMT connected to secondary node, does not show alarm information if the primary node is down

From DocWiki

(Difference between revisions)
Jump to: navigation, search
m (1 revision)
 
(6 intermediate revisions not shown)
Line 1: Line 1:
-
== RTMT does not show alarm info if the primary node is out of service ==
+
== RTMT does not show alarm info if the primary node is down ==
{| border="1"
{| border="1"
Line 16: Line 16:
<br>
<br>
-
#When the primary node is in service, sign in to MediaSense administration, and then enter: '''<nowiki>https://<ip address>:8443/ccmadmin/serviceParamEdit.do</nowiki>&nbsp;'''in the browser address field&nbsp;to access the Unified CM server parameter configuration page.  
+
#When&nbsp;both nodes&nbsp;are in service, sign in to MediaSense Administration on the Primary node, and then enter: '''<nowiki>https://<ip address>:8443/ccmadmin/serviceParamEdit.do</nowiki>&nbsp;'''in the browser address field&nbsp;to access the Unified CM server parameter configuration page.  
#Activate the Failover Collector for the Cisco AMC service.
#Activate the Failover Collector for the Cisco AMC service.
|-
|-
! '''Release'''  
! '''Release'''  
-
| &nbsp;Release 8.5(1), Release 8.5(2), Release 8.5(3), Release&nbsp;8.5(4)
+
| &nbsp;All.
|-
|-
! '''Associated CDETS #'''  
! '''Associated CDETS #'''  
| &nbsp;CSCtx41763
| &nbsp;CSCtx41763
 +
[[Category:Cisco_MediaSense,_Release_8.5]]
 +
[[Category:Cisco_MediaSense,_Release_9.0]]
|}
|}
-
 
-
<br><br>
 
-
 
-
[[Category:Cisco_MediaSense,_Release_8.5]]
 
-
'''
 

Latest revision as of 18:57, 14 August 2012

RTMT does not show alarm info if the primary node is down

Problem Summary The Unified Real Time Monitoring Tool (Unified RTMT) is connected to the secondary node, but after logging in to RTMT, alarm information is not shown. Instead, an error is reported.
Error Message Error polling alert status - AMC service is down
Possible Cause By default, the Primary Collector for the Alert Manager and Collector Service (AMC) is configured on the primary node, and the Failover Collector is not active. If the primary node is down, there is no available collector to which RTMT can connect. 
Recommended Action


  1. When both nodes are in service, sign in to MediaSense Administration on the Primary node, and then enter: https://<ip address>:8443/ccmadmin/serviceParamEdit.do in the browser address field to access the Unified CM server parameter configuration page.
  2. Activate the Failover Collector for the Cisco AMC service.
Release  All.
Associated CDETS #  CSCtx41763

Rating: 0.0/5 (0 votes cast)