ONS SONET TL1 Reference Guide R8.5.x -- TL1 Errors
From DocWiki
Note: The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration.
This chapter provides TL1 error information supported by the Cisco ONS 15454, ONS 15327, ONS 15600, and ONS 15310-CL. For alarm information, refer to the platform-specific procedure guide, troubleshooting guide, and reference manual.
Errors
Errors can be generated by any command or command response message. Table 3-1 through Table 3-65 list errors alphabetically by error code. The format of an error message is as follows:
SID DATE TIME
M CTAG DENY
<ERRCDE>
/* <ERRMSG> */
;
Table 3-1: ENEQ Errors
| ENEQ Error Messages |
|---|
|
At Least One Equipment Is Not Plugged |
|
Communication Failed |
|
Control Not Provisioned |
|
Cost Not Found |
|
EnvControl IF Is Not Found |
|
Environmental Control Interface Not Found |
|
Equipment Is Deleted |
|
Equipment Must Be Present |
|
Equipment Not Found |
|
Equipment Not Present |
|
Equipment Not Provisioned |
|
IP Address Not Found |
|
IP Mask Not Found |
|
Internal Communication Error |
|
Next Hop Not Found |
|
No standby present |
|
No standby provisioned |
|
Not Equipped |
|
Sensor IF Is Not Found |
|
Sensor Interface Not Found |
|
Standby not in valid state, please wait |
|
TID Not Found |
Table 3-2: IBEX Errors
| IBEX Error Messages |
|---|
|
Extra Datablock |
|
Extra parameters |
|
Invalid AID Block. Extra Datablock |
|
Invalid Payload Block. Extra Datablock |
Table 3-3: ICNV Errors
| ICNV Error Messages |
|---|
|
AIS on LOF Not Supported |
|
AISV on AIS Not Supported |
|
Admin SSM Not Supported |
|
Cannot Change Threshold Values On Protect Port |
|
Cannot Set DCC When G709 Is Enabled |
|
Cannot set Timer value if FTP server is not enabled |
|
Cross Connect Not Supported By XC Mode |
|
Equipment Does Not Match Request |
|
Equipment In Use |
|
Impedance Not Supported With Current Configuration |
|
Inhfelpbk Not Supported |
|
Invalid Command |
|
Invalid VLAN Remapping |
|
Operation Not Supported By This Card |
|
Operation Not Supported On This Shelf |
|
PDIP Generation Not Supported |
|
PDIP Not Supported |
|
PM Threshold Type Not Supported |
|
PM Type Not Supported |
|
Payload Does Not Match Request |
|
Performance Monitoring Type Not Supported |
|
Protection Type Not Supported in SONET Media |
|
SaBit Not Supported With Current Configuration |
|
Senddus Not Supported |
|
Syncmap Not Supported |
|
Syncmsg Not Supported |
|
Threshold Type Not Supported |
|
Trace Not Supported On Protect Trunk Port |
|
Unidirectional Not Supported |
|
VT Map Not Supported |
|
XC MODE Not Supported |
Table 3-4: IDMS Errors
| IDMS Error Messages |
|---|
|
Data Missing |
|
Loopback Type Missing |
|
Missing Internal Data |
Table 3-5: IDNC Errors
| IDNC Error Messages |
|---|
|
Invalid Data |
|
Invalid PST Value |
|
Invalid SST Value |
|
PRI source cannot be INTERNAL when SEC source is not INTERNAL |
|
PRI source cannot be INTERNAL when THIRD is not INTERNAL |
|
Primary Source Cannot Be INTERNAL When Secondary Source Is Not INTERNAL |
|
Primary Source Cannot Be INTERNAL When Third Source Is Not INTERNAL |
|
Primary Source Cannot Be NONE When Secondary Source Is Not NONE |
|
Primary Source Cannot Be NONE When Third Source Is Not NONE |
|
SEC source cannot be INTERNAL when THIRD is not INTERNAL |
|
SSM not supported on SDH |
|
Secondary Source Cannot Be INTERNAL When Third Source Is Not INTERNAL |
|
Secondary Source Cannot Be NONE When Third Source Is Not NONE |
|
Third source must be INTERNAL |
Table 3-6: IDNV Errors
| IDNV Error Messages |
|---|
|
2F-BLSR Architecture Does Not Permit Manual/Forced Span Switching |
|
ADM Peer Group Name Exceeds Maximum Length |
|
AIS On Terminal Loopback Not Supported |
|
AISONLPBK Not Supported |
|
AMPLMODE Not Supported |
|
AUTO ALS Mode Not Allowed With Digital Wrapper Disabled |
|
AUTO Trace Mode Not Allowed |
|
Alarm Message Must Be Enclosed Within a Pair of Quotes |
|
Alarm Message Required for MISC |
|
Alarm Type Exceeds Maximum Length Allowed |
|
At least an XC10G XC card is needed for this equipment type |
|
BERT Diagnostics Limited To VT Cross connections |
|
CALOPWR Not Supported |
|
CALTILT Not Supported |
|
CHPOWER Not Supported |
|
CKTID Exceeds Maximum Length |
|
CMDMDE Only Applicable when Creating/Deleting Protection Group |
|
Calibration Power Not Allowed |
|
Cannot Access DCC |
|
Cannot Change Protection Type |
|
Cannot Change XC Mode |
|
Cannot Delete Dynamic TDC Entry |
|
Cannot Edit NAME When ADM Peer Group Not Present |
|
Cannot Edit NAME When Regeneration Group Not Present |
|
Cannot Modify Circuit Size While Active Equipment |
|
Cannot turn off proxy server or firewall while in secure mode |
|
Card Does Not Support Synchronization/Timing Parameters |
|
Card Mode Incompatible With Configured Payload Type |
|
Command Not Valid On Protect Card |
|
Configuration Does Not Support AUTO ALS Mode |
|
Current Interval Not Supported For RMON PMs |
|
DCC Not Supported In Transparent Term Mode |
|
DCC is in use |
|
DS1 Mode Not Supported |
|
Data Rate Already Provisioned |
|
Description Too Long |
|
Description cannot be more than 32 characters |
|
Distance Extension Not Enabled |
|
EXPGAIN Parameter Not Supported By Amplifier Facility |
|
Edit FMT on an Invalid Card |
|
Edit FMT with an Invalid Data |
|
Edit Line Code Failed |
|
Edit Line Code on an Invalid Card |
|
Equipment Does Not Support ADM Peer Group |
|
Equipment Does Not Support EXPWLEN |
|
Equipment Does Not Support FCS |
|
Equipment Does Not Support Fast Ring Protection Role |
|
Equipment Does Not Support Fast Ring Protection State |
|
Equipment Does Not Support PROTID |
|
Equipment Does Not Support PRTYPE |
|
Equipment Does Not Support Payload Type |
|
Equipment Does Not Support RDIRN |
|
Equipment Does Not Support RVRTV |
|
Equipment Does Not Support RVTM |
|
Equipment Does Not Support Regeneration Group |
|
Equipment Does Not Support SUPERBLKS |
|
Equipment Incompatible For Regeneration Group |
|
Flow Control Value Not Supported |
|
Frame Format Contains Invalid Data |
|
Frame Format Not Supported On Equipment |
|
GCC Not Supported On CLNT Port |
|
GFP Buffer Out Of Range |
|
High Threshold Should Be Lower Than Extreme High |
|
Incompatible Equipment Type For Protection |
|
Incompatible Equipment Type |
|
Incompatible New Equipment Type |
|
Incompatible Protect Slot For Protection |
|
Input, Data Not Valid |
|
Interval Out Of Range |
|
Invalid AID For PCA Cross-Connection |
|
Invalid Alarm Message |
|
Invalid Buffer Type |
|
Invalid Card Mode For Equipment Type |
|
Invalid Committed Rate |
|
Invalid Community |
|
Invalid Data For 2F-BLSR |
|
Invalid Data Rate |
|
Invalid Drop Path |
|
Invalid Enable Value |
|
Invalid Equipment Type |
|
Invalid Ethernet Frame Size |
|
Invalid Expected Path Trace Message |
|
Invalid Fast Ring Protection Role |
|
Invalid Fast Ring Protection State |
|
Invalid Holdoff Timer Value |
|
Invalid Interval |
|
Invalid Log Name |
|
Invalid MONLEV Value |
|
Invalid MONTYPE Value |
|
Invalid MTU Size |
|
Invalid MAC Address |
|
Invalid NI Mode |
|
Invalid Next Hop |
|
Invalid Notification Code |
|
Invalid PM Interval |
|
Invalid PPM Port |
|
Invalid Port Number |
|
Invalid Protect Group Identifier |
|
Invalid PROTID |
|
Invalid QNQ Mode |
|
Invalid Recovery Pulse Width |
|
Invalid Reference |
|
Invalid Regeneration Group AID |
|
Invalid Regeneration Group Configuration |
|
Invalid Report Interval |
|
Invalid Start Time |
|
Invalid Static Route Destination |
|
Invalid Switch Command |
|
Invalid Switch Type For BLSR |
|
Invalid TAP Number |
|
Invalid TXCOUNT Or RXCOUNT |
|
Invalid TXCOUNT |
|
Invalid Threshold Value Ordering |
|
Invalid Time Offset |
|
Invalid Timer Value |
|
Invalid Trace Level |
|
Invalid User Name |
|
Invalid VCAT Group Name |
|
Invalid area ID, format is nnn.nnn.nnn.nnn |
|
J0 Section Trace Not Supported In Transparent Term Mode |
|
Keyword All Not Allowed |
|
Line Code Not Supported |
|
Link Credit Out Of Range |
|
Link Recovery And Distance Extension are Mutually Exclusive |
|
Low Threshold Should Be Greater Than Extreme Low |
|
MAN TRCMODE Not Allowed with NULL EXPTRC |
|
Maximum Number Of Protected VLAN Reached |
|
Maximum Number Of Routes Reached |
|
Maximum Number Of VLAN Reached |
|
Multiple AIDs Not Allowed |
|
Multiple PROTID Not valid |
|
Multiple Protection Group Card Slot Identifiers Not Allowed |
|
Multiple References Not Allowed |
|
Must Provide PROTID for Adding Working Modules |
|
NEWSHELFID Required When Changing SHELFROLE To SC |
|
Next Hop Conflicts Default Router |
|
Node Has Default GRE Tunnel |
|
Null Userid Or Range In Userid List Not Allowed |
|
Number Of Reports Is Negative |
|
OSRI Not Supported |
|
Only One Trunk Required For Card Mode |
|
PPM Does Not Exist |
|
PPM Type Parameter Not Supported By This Card |
|
PRIVLVL Not Allowed When PAGE = 0 |
|
PRIVLVL Not Allowed Without PAGE, PCND, or TMOUT |
|
PRIVLVL Required With PAGE, PCND, Or TMOUT |
|
Parameter Not Supported By Payload Type |
|
Parameter Not Supported By This Optical Node Type |
|
Parameter Not Supported On Protect Trunk Port |
|
Payload Mapping Type Incompatible With G.709 Settings |
|
Payload Type Does Not Support AUTO ALS Mode |
|
Payload Type Does Not Support DCC |
|
Payload Type Does Not Support IS-AINS State |
|
Payload Type Does Not Support OTN/FEC |
|
Payload Type Not Supported |
|
Peer Card Not Present |
|
Peerid Must Be Different From Aid |
|
Port Name Exceeds Maximum Length |
|
Port Unsupported in Card Mode |
|
Power Setpoint Adjust Failed |
|
Protect Card Does Not Support Protection Type |
|
Protect Slot Not Provisioned |
|
Protection Group Card Slot Identifier Field Required |
|
Protection Group Does Not Exist |
|
Protection Group Name Cannot Be Null |
|
Protection Group Name Exceeds Maximum Length |
|
QNQ Entry Not Provisioned |
|
REFTILT Not Supported |
|
RMON Threshold Not Supported |
|
Rate Capacity Exceeded |
|
Regeneration Group Name Exceeds Maximum Length |
|
Requested CRSTYPE Not Supported |
|
Retime Not Supported |
|
Ring Lockout BLSR Switching Is Not Supported |
|
SDCC is in use |
|
SHELFROLE Field Must Be SC With NEWSHELFID |
|
Shelf Role Invalid For Equipment Type |
|
Span Lockout of Working on BLSR Switching Is Not Supported |
|
Squelch Not Allowed With Current Setting |
|
Static Route Cannot Be 255.255.255.255 |
|
Static Route Cannot Be Same As Class A Broadcast Address |
|
Static Route Cannot Be Same As Class B Broadcast Address |
|
Static Route Cannot Be Same As Class C Broadcast Address |
|
Static Route Cannot Be Same As Default Router Mask |
|
Static Route Cannot Be Same As Internal Network |
|
Static Route Cannot Be Same As Node Broadcast Address |
|
Static Route Cannot Be Same As Node IP |
|
Static Route Cannot Be Same As Node Subnet |
|
Static Route Cannot Be Same As Old Class E Address |
|
Static Route Cannot be Same As Local Net |
|
Switch Type Is Not Allowed On 1+1 |
|
TID Name Exceeds Maximum Length |
|
TMPER Type Not Supported |
|
Tap Out Of Range |
|
Term Mode Does Not Support Synchronization/Timing Parameters |
|
Threshold Increment Invalid |
|
Threshold Value Out Of Range |
|
Trace Level Not Supported By Client Port |
|
Trace Level Required |
|
Trace Not Supported In Transparent Term Mode |
|
Transmitted Path Trace Message not supported |
|
Transport Mode Invalid For Equipment Type |
|
Unsupported Or Incompatible Termination Mode |
|
Unsupported Protection Option |
|
VLAN Name Exceeds Maximum Length |
|
VLAN Out Of Range |
|
VOA Not Supported |
|
VOA Out Of Range |
|
Value Or Threshold Read Only |
|
Value Out Of Range |
Table 3-7: IDRG Errors
| IDRG Error Messages |
|---|
|
DST Not Supported For The Time Zone |
|
Difference Value Range Error |
|
Invalid DURAL Value |
|
Invalid GFPBUF Value |
|
Invalid MXINV Value |
|
Invalid MXINV or DURAL Value |
|
Invalid PAGE Value |
|
Invalid PAGE or PCND Value |
|
Invalid PCND Value |
|
Invalid PDIF Value |
|
Invalid PINT Value |
|
Invalid PJMON Value |
|
Invalid POLD Value |
|
Invalid TMOUT Value |
|
Invalid Threshold Value |
|
Invalid Time Zone |
|
Invalid Trap Destination |
|
Invalid Trap Port |
|
Invalid UOUT Value |
|
Invalid Watermark Value |
|
PJMON Out Of Range |
Table 3-8: IIAC Errors
| IIAC Error Messages |
|---|
|
AID Does Not Match with Requested BLSR Path Type |
|
AID PARSE ERROR |
|
ALL AID Not Allowed |
|
ALL, Ranging and Grouping Are Not Supported for Hard Reset |
|
ALL, Ranging and Grouping Are Not Supported |
|
AID validation failed |
|
BERT Diagnostic Cross connection Source Must Equal Destination |
|
BLSR East and West On Same Slot Not Allowed |
|
BLSR Time Slot Mismatch |
|
Bad Ring Id |
|
CCT=1WAY Not Allowed For The Card |
|
Cannot Create Schedule On Protect Card |
|
Cannot Access One Plus One Protect Line |
|
Cannot Make Changes To Protect Card |
|
Cross-Connection Cannot Overlap PCA Boundary |
|
Cross-Connection Cannot Use GIGE Ports When In Transponder Mode |
|
Cross-connection PathWidth Not Supported by Card |
|
DS1 Out of Range |
|
EQPT Prot AID parse failed |
|
Equipment Can Not Be Provisioned On Low Speed Slot |
|
Equipment Does Not Match Request |
|
Equipment Does Not Support This Type Of Cross-connection |
|
Equipment Type Is Same As Provisioned Equipment |
|
Expected Trace Not Supported On This Card Type |
|
Expected Trace String Exceeds Max Length (62) |
|
Expected Trace String Exceeds Maximum Length |
|
FAC parse failed |
|
Incoming Trace Not Supported On This Card Type |
|
Incorrect Card Type |
|
Input, Invalid Access |
|
Invalid AID |
|
Invalid Cross-connection Name |
|
Invalid Cross-connection Path Number |
|
Invalid DRI Node Type |
|
Invalid DRI Topology |
|
Invalid DS1 AID |
|
Invalid FROM AID |
|
Invalid G1000 Facility Port |
|
Invalid Month Or Day |
|
Invalid Node Side |
|
Invalid NodeId |
|
Invalid Operation On Drop AID |
|
Invalid PJMON Value |
|
Invalid PM Direction parameter |
|
Invalid Protect AID or Working AID |
|
Invalid Protect AID |
|
Invalid RFROM AID |
|
Invalid RFROMEND AID |
|
Invalid RFROMSTART AID |
|
Invalid RTO AID |
|
Invalid RTOSTART AID |
|
Invalid Reference |
|
Invalid RingID |
|
Invalid Roll From And/Or Roll To AID |
|
Invalid Source AID |
|
Invalid Source/Destination AID Count For Cross-Connection Type |
|
Invalid TAP |
|
Invalid TO AID |
|
Invalid TPORT AID |
|
Invalid Time |
|
Invalid VCG Member Number |
|
Invalid Year |
|
Invalid fac-n-m input |
|
J1 Trace Not Supported On This Card |
|
List AID Not Allowed For ALL AID |
|
List Or All AID Not Supported |
|
Loopback type mismatch |
|
LpbkType Does Not Match |
|
Multiple AIDs Not Allowed With All AID |
|
Multiple AIDs Not Allowed |
|
Multiple AIDs Not Supported |
|
Multiple Destination AID Exceeds Limit |
|
Multiple Destinations Not Supported By Cross-Connection |
|
Multiple Source AID Exceeds Limit |
|
Multiple TAP AIDs Not Supported |
|
Multiple AIDs Not Allowed |
|
No TPORT With ONE-PORT-BI TRANS Mode |
|
No TPORT With Removing TRANS Mode |
|
Not Allowed On 1+1 Protect Line |
|
Not Allowed On BLSR Protect Line |
|
Not Allowed On Protect Line |
|
Optional AIDs Are Not Supported |
|
Ranging and Grouping Are Not Supported for Soft Reset |
|
RingID Does Not Match with AID Number |
|
TPORT Must Use The Same Slot As The Aid |
|
TPORT Supports Only A Single AID |
|
Trace Format Not Supported On This Card Type |
|
Trace Mode Not Supported On This Card Type |
|
Trace Not Supported For Current Configuration |
|
Trace String Exceeds Maximum Length |
|
Transmit Trace Not Supported On This Card Type |
|
Path Protection Cross-Connections Not Allowed For The Facility Of Data Card |
|
Use Of TPORT Argument Requires Use Of TRANS |
Table 3-9: IICM Errors
| IICM Error Messages |
|---|
|
Command not implemented yet... |
|
Command not supported in this release |
|
Input, Invalid Command |
|
Input, Invalid MOD1 |
|
Input, Invalid MOD2 |
|
Input, Invalid VERB |
|
Memory Allocation Error |
Table 3-10: IICT Error
| IICT Error Message |
|---|
|
Invalid Correlation Tag |
Table 3-11: IIDT Errors
| IIDT Error Messages |
|---|
|
'%xx' Encoding Error In URL Parsing |
|
0 Sec Revertive Time Not Supported |
|
2F-BLSR Does Not Support SRVRTV/SRVTM/EASTPROT/WESTPROT Parameters |
|
AUTO trace mode not supported |
|
CMDMDE Must Be FRCD |
|
Can Not Delete A Schedule Which Does Not Exist |
|
Cannot Activate To Older Software |
|
Cannot Add And Remove Drops Together |
|
Cannot Create More RMON Threshold |
|
Cannot Edit OSPF When Both SDCC and LDCC are Enabled |
|
Cannot Revert From R2 To R1 |
|
Cannot Revert To Newer Software |
|
Cannot Revert While In Permanent Secure Mode |
|
Cannot Revert While In Secure Mode |
|
Command Already In Progress |
|
DEST Incompatible With RFR Type |
|
DEST Incompatible With SWDL Type |
|
DEST Required For RFBU Type |
|
Duplicate BLSR Working/Protect Facilities |
|
Duplicate Performance Monitoring Schedule |
|
Duplicate RMON Threshold |
|
Duplicate Schedule |
|
Error Adding New Schedule |
|
FRCD mode not supported |
|
FTTD Host Cannot Be IP Address |
|
FTTD Is Not Supported. Only Direct File Transfers Are Supported |
|
FTTD URL Missing |
|
Facility Already in OSC Group |
|
File Name Missing In URL |
|
Flash Manager Not Active |
|
Hostname Missing In URL |
|
IOS Config File Too Big |
|
Invalid 2 Fiber Blsr Parameter |
|
Invalid BLSR Mode |
|
Invalid BLSR Protect Facility |
|
Invalid BLSR Working Facility |
|
Invalid Data Parameter |
|
Invalid East Protect Port |
|
Invalid East Working Port |
|
Invalid FTTD Host |
|
Invalid NSAP Character |
|
Invalid NSAP Length |
|
Invalid NSAP Selector |
|
Invalid NSAP |
|
Invalid OSC Group Facility |
|
Invalid Phase Number |
|
Invalid Port In URL |
|
Invalid Revertive Time |
|
Invalid Shelf Id 1 For SC |
|
Invalid Software Switch Type |
|
Invalid State Transition Request |
|
Invalid State Value |
|
Invalid Type Value In FTP URL. Only 'a', 'i', or 'd' Is Allowed. |
|
Invalid West Protect Port |
|
Invalid West Working Port |
|
Invalid type= Syntax In FTP URL |
|
Loopback type not supported |
|
Mandatory FTP URL Not Provided |
|
Maximum Performance Monitoring Schedule Limit Reached |
|
Memory Out Of Range |
|
Missing/Invalid Destination |
|
Missing/Invalid Source |
|
NSAP FTTD Hosts Unsupported |
|
No TID matches FTTD hostname |
|
Non-IP Hostname In FTP URL |
|
Non-IP Hostname or Invalid TID In FTP URL |
|
Null Outputs In URL Parsing |
|
Only IS PST Is Supported |
|
Only MAINT STATE Supported |
|
Only NORM CMD_MODE Is Supported |
|
Only OOS PST Is Supported |
|
Only OVWRT of YES is Allowed For Uploads |
|
Only Port 21 Is Supported |
|
Only SWDL Is Supported For The xfertype Argument |
|
Only Type 'a' Is Supported In The COPY-IOSCFG FTP URL |
|
Only Type 'i' Is Supported In The COPY-RFILE FTP URL |
|
Password Missing In URL |
|
Performance Monitoring Schedule Does Not Exist |
|
Port Missing In URL |
|
RFBU Type Required With RFILE-LOG Aid |
|
Reach Limits Of MAX Schedules Allowed. Cannot Add More |
|
SRC Incompatible With RFBU Type |
|
SRC Required For RFR Type |
|
SRC Required For SWDL Type |
|
SWDL Incompatible With RFILE-COMPDB Aid |
|
SWDL Incompatible With RFILE-PKG Aid |
|
Software Activate/Revert Failed |
|
Software Not Available For Switch |
|
Terminal Loopback is not supported |
|
The URL Contains Unsafe Characters. Please Encode |
|
Unknown Error Processing FTP URL |
|
Unsupported Locn Value |
|
Username Missing In URL |
|
ftp:// Missing In FTP URL |
|
fttd:// Missing In FTTD URL |
Table 3-12: IIFM Errors
| IIFM Error Messages |
|---|
|
Invalid AID Block. Invalid Data Format |
|
Invalid Alarm Type - Must Conform To TL1 Rules |
|
Invalid Data Format |
|
Invalid Password |
|
Invalid Payload Block. Invalid Data Format |
|
Invalid User ID |
Table 3-13: IIPG Errors
| IIPG Error Messages |
|---|
|
Configuration Requires Transparent Termination Mode |
|
Equipment Payload Type Incompatible For Regeneration Group |
|
Payload Type Requires Squelch Card Mode |
|
Payload Type Requires Transparent Termination Mode |
|
Transparent Termination Mode Required For Regeneration Group |
Table 3-14: IISP Errors
| IISP Error Messages |
|---|
|
Input, Garbage |
|
Invalid AID Block. Extraneous ',' Found |
Table 3-15: IITA Errors
| IITA Error Messages |
|---|
|
GNE: Input, Invalid Target Identifier |
|
Input, Invalid Target Identifier |
Table 3-16: INUP Errors
| INUP Error Messages |
|---|
|
EXTRNG Configuration Is Not Supported |
|
General Block Unsupported |
|
Missing mandatory field |
|
NODEID Configuration Is Not Supported |
|
RNGID Configuration Is Not Supported |
|
RNGMAPAUTO Configuration Is Not Supported |
|
RNGWTR Configuration Is Not Supported |
Table 3-17: IPEX Errors
| IPEX Error Messages |
|---|
|
Duplicate N/V field |
|
Invalid Payload Block. Extra Parameters |
Table 3-18: IPMS Errors
| IPMS Error Messages |
|---|
|
Invalid AID Block. Missing Mandatory Field |
|
Invalid Payload Block. Missing Mandatory Field |
|
Invalid syntax |
|
Missing mandatory field |
|
Parameter Missing |
Table 3-19: IPNC Errors
| IPNC Error Messages |
|---|
|
Cannot Change Existing Protection Type |
|
Cross-connect Doesn't Have Path Protection Path Selector |
|
Description Too Long |
|
Expected Duplex Not Supported |
|
Expected Speed Not Supported |
|
Invalid Auto Negotiate Value |
|
Invalid Encapsulation Type |
|
Invalid Flow Control Value |
|
Invalid Maximum Frame Size |
|
Invalid Oprnominal Value |
|
Invalid Parameter |
|
Invalid Trans Value |
|
Parameter Not Valid |
|
Parameters Are Not Consistent |
|
Parameters Not Compatible |
|
Selective auto Negotiate Cannot be enabled |
Table 3-20: IPNV Errors
| IPNV Error Messages |
|---|
|
AID or Condition Must Be Specified |
|
Bad IP Configuration Parameter |
|
Bad Parameter |
|
Bad Reference |
|
Cannot Set Expected Path Trace For Source Path |
|
Cannot Set Expected Path Trace In Auto Mode |
|
Cannot Set Outgoing Path Trace For Drop Path |
|
Cross-Connection Does Not Have Path Protection Path Selector |
|
DRITYPE Not Supported For Connection Type |
|
Empty parameter |
|
Exercise Is Not Allowed On Protected Facility |
|
Expected Trace String Exceeds Max Length (62) |
|
Facility Does Not Support Montype |
|
Far End Loopback Type Not Supported In Current Framing Format |
|
Far End Performance Monitoring Values Not Supported |
|
Holdoff Timer Not Supported For Non-DRI Cross-Connections |
|
INT Not Valid For BITS-OUT |
|
INVALID SAMPLE TYPE |
|
Internal-Ip Lookup Failed |
|
Internal-Network Nodes Lookup Failed |
|
Invalid BITS Framing |
|
Invalid BITS Rate |
|
Invalid Clock Source |
|
Invalid Condition Type |
|
Invalid DRITYPE |
|
Invalid Default Router Address |
|
Invalid IIOP Port number |
|
Invalid IP Address |
|
Invalid IP Configuration Parameter |
|
Invalid IP Mask |
|
Invalid IP Port Number |
|
Invalid Link Termination Port |
|
Invalid MONLEV Value |
|
Invalid OSPF Cost |
|
Invalid PM register |
|
Invalid Parameter |
|
Invalid Payload Block. Empty Parameter |
|
Invalid Report Interval |
|
Invalid SNTP Host Address |
|
Invalid Start Time |
|
Invalid Switch Command For Synchronization |
|
Invalid Switch Type |
|
Invalid Threshold Value |
|
Invalid Why Parameter |
|
New Source Must Be Specified |
|
Node Name Exceeds Maximum Length |
|
Number Of Reports Is Negative |
|
Optical Performance Monitoring Not Supported For This Card Type |
|
PM Not Supported |
|
Parameter Not Valid |
|
Path is not associated with Path Protection Path Selector |
|
Payload Does Not Support Optics Montypes |
|
Primary Reference Incompatible With Timing Mode |
|
Protection Type Does Not Support Reversion Mode |
|
Protocol Does Not Support This State |
|
RMON PM History Not Supported |
|
Reference Type Not Supported |
|
SPNWTR Parameter Not Supported |
|
STARTUP TYPE MUST BE RISING FOR ABSOLUTE SAMPLE TYPE |
|
Secondary Reference Incompatible With Timing Mode |
|
Synchronization Source Already Defined For Protection Group |
|
Synchronization Source Already Defined For The Slot |
|
TL1 Can Not Set Its Own Access Level |
|
TMGREF Parameter Not Supported |
|
Third Reference Incompatible With Timing Mode |
|
Time Period Not Applicable |
|
Timing Mode Not Compatible |
Table 3-21: NO Errors
| NO Error Messages |
|---|
|
No Applicable PM Data |
|
No Error |
Table 3-22: PICC Errors
| PICC Error Messages |
|---|
|
AID Required |
|
AID does not match this session UID |
|
Bad Password Toggling - New Password Same As A Prior Password |
|
Can't logout if user is not logged in |
|
Can't change own security level |
|
Can't login |
|
Command Not Available to this User Level |
|
IP Address Display Is Suppressed |
|
Invalid User Access Privilege Value |
|
Invalid User Identifier - Must Conform To TL1 Rules |
|
Invalid User Password - Must Conform To Provisioned Password Rules |
|
Invalid User Password - Must Conform To TL1 Rules |
|
Logout failed |
|
New Password Too Similar To Old Password |
|
Password Cannot Be Changed Before Minimum Wait Time Expires. |
|
Password Must Be Changed Before Continuing |
|
Unexpected Default Case |
|
Unknown CORBA Exception (Internal Error) |
|
Unknown User |
|
User Access Privilege Required |
|
User Already Exists |
|
User Identifier Exceeds Maximum Length Allowed |
|
User Not Authorized |
|
User Password Required |
Table 3-23: PIMA Errors
| PIMA Error Message |
|---|
|
Memory Out Of Range |
Table 3-24: PIUC Errors
| PIUC Error Messages |
|---|
|
Cannot Delete The Logged In User |
|
Cannot Remove The Last Superuser |
|
Unauthorized change of PID |
|
Unauthorized |
|
User Currently Logged Into Another Session |
|
User Is Not Superuser |
|
User Not Allowed To Change User Access Privilege |
|
User Not Allowed To Change User Password |
|
User Not Allowed To Disable/Enable Self |
|
User Not Allowed To Terminate Self |
|
User Not Logged In |
Table 3-25: PLNA Error
| PLNA Error Message |
|---|
|
Login Not Active |
Table 3-26: RALB Errors
| RALB Error Messages |
|---|
|
GNE: All ENE Connections in Use |
|
Requested DCC In Use |
Table 3-27: RANB Error
| RANB Error Message |
|---|
|
GNE: No Response from ENE - IENE |
Table 3-28: RNBY Errors
| RNBY Error Message |
|---|
|
Software upgrade in progress |
Table 3-29: RRNG Errors
| RRNG Error Messages |
|---|
|
I/O Slot Out Of Range |
|
Invalid Slot Number For SDH Electrical Cards |
|
Invalid Slot Number |
Table 3-30: RTBY Errors
| RTBY Error Messages |
|---|
|
Connection In Service |
|
Side In Service |
|
TAP Already In Use |
|
TAP Number In Use |
Table 3-31: RTEN Errors
| RTEN Error Messages |
|---|
|
Cannot Access VT |
|
Cannot Change Access Mode |
|
Cannot Set Access Mode |
|
Invalid Access Mode |
|
Invalid STS TAP Number |
|
Invalid TAP AID |
|
Invalid TAP Mode |
|
Invalid TAP Number |
|
Invalid VT Path TAP Number |
|
Requested TAP Does Not Exist |
|
Requested Tap Busy |
|
TAP Not Found |
Table 3-32: SAAL Error
| SAAL Error Message |
|---|
|
Already Allowed |
Table 3-33: SAAS Error
| SAAS Error Message |
|---|
|
Equipment Already Provisioned |
Table 3-34: SADC Errors
| SADC Error Messages |
|---|
|
Already Disconnected |
|
GNE: ENE is down |
|
TAP Not Connected |
Table 3-35: SADS Error
| SADS Error Message |
|---|
|
Loopback Applied On Cross-connection |
Table 3-36: SAIN Errors
| SAIN Error Messages |
|---|
|
Already Inhibited |
|
Already Locked On |
|
Already Locked Out |
Table 3-37: SAIS Errors
| SAIS Error Messages |
|---|
|
Connection In Service |
|
Port Already In Service |
Table 3-38: SAMS Errors
| SAMS Error Messages |
|---|
|
Already In Clear Maintenance State |
|
Already In Force Maintenance State |
|
Already In Lockout Maintenance State |
|
Already In Manual Maintenance State |
Table 3-39: SAOP Errors
| SAOP Error Messages |
|---|
|
Control Already Operated |
|
Control Already Released |
|
Control Operated In Mntry |
Table 3-40: SAOS Errors
| SAOS Error Messages |
|---|
|
Port Already in IS-AINS |
|
Port Already In OOS-MT |
|
Port Already Out Of Service |
Table 3-41: SAPR Errors
| SAPR Error Messages |
|---|
|
Cannot Provision Regeneration Group When A Protection Group Is Present |
|
Card Already In A Regeneration Group |
|
Card Has Y Cable Protection |
|
Peer Card Already In A Regeneration Group |
|
Peer Card Has Y Cable Protection |
Table 3-42: SARB Errors
| SARB Error Messages |
|---|
|
GNE: All Gateways in Use |
|
System Memory Exhausted. Retry A Few Seconds Later |
Table 3-43: SCAT Errors
| SCAT Error Messages |
|---|
|
Connection Already In Loopback |
|
Connection Already In Test Access |
|
Connection Is Tapped |
|
End Point Is Already Connected |
|
STS Is Already Used |
|
Test Access Busy |
|
VT Is Already Used |
|
Would exceed max number of drops |
Table 3-44: SDBE Errors
| SDBE Error Messages |
|---|
|
AID Parser Failed |
|
Asymmetric VCG Not Supported |
|
Bad Parameter |
|
Cannot Access Alarms |
|
Cannot Access Conditions |
|
Cannot Access Controls |
|
Cannot Access Date/Time |
|
Cannot Access Defaults Description |
|
Cannot Access Environmental Settings |
|
Cannot Access Equipment |
|
Cannot Access Facility |
|
Cannot Access IP Configuration |
|
Cannot Access IP Display Suppression |
|
Cannot Access Interface |
|
Cannot Access Node ID |
|
Cannot Access Node Name |
|
Cannot Access Object |
|
Cannot Access Orderwire |
|
Cannot Access Protection Group |
|
Cannot Access Protection State |
|
Cannot Access SNMP Ip Addr |
|
Cannot Access SNTP Host |
|
Cannot Access STS |
|
Cannot Access Security Mode |
|
Cannot Access Software Version |
|
Cannot Access Synchronization Configuration |
|
Cannot Access Timezone |
|
Cannot Access Trace Information |
|
Cannot Access VT Performance Monitoring Parameters |
|
Cannot Access VT |
|
Cannot Configure Extension Byte For Current Configuration |
|
Cannot Configure SYNC |
|
Cannot Create 1+1 Protection Group |
|
Cannot Edit STS |
|
Cannot Get Line Information |
|
Cannot Get Synchronization Configuration |
|
Cannot Set Date When Using SNTP |
|
Cannot Set Date |
|
Cannot Set IP Configuration |
|
Cannot Set Node Name |
|
Cannot Set Pointer Justification Monitoring Parameter (PJMON) |
|
Cannot Set SNTP Host Configuration |
|
Cannot Set Timezone |
|
Cannot Soft Reset System |
|
Card Type Not Supported |
|
DLT prg Failed |
|
Delete Protection Group Failed |
|
Equipment Not Found |
|
Ethernet Port Not Provisioned |
|
Facility Does Not Exist |
|
Facility Does Not Match Request |
|
Facility Does Not Support Mac Address |
|
Facility Is Not Provisioned |
|
Facility Not Provisioned |
|
File Transfer In Progress |
|
Get Sonet Line Info Failed |
|
Getting SONET sync configurations |
|
IOS Config Update In Progress |
|
IP Configuration Failed |
|
Incompatible Parameter Values |
|
Incorrect Facility Type |
|
Interface Does Not Exist |
|
Interface Does Not Support Loopback Type |
|
Internal Access Failed |
|
Internal Database Error |
|
Invalid Command |
|
Invalid Cross Connect Type For VCG |
|
Invalid DCC |
|
Invalid Mondat Format |
|
Invalid Montm Format |
|
Invalid Performance Monitoring Mode |
|
Invalid Protection Group |
|
Invalid Time Period |
|
Invalid Trace Mode for Card Type |
|
LCAS Not Supported By This Card |
|
Location Value Invalid |
|
Loopback Is Invalid |
|
Loopback Port In Service |
|
Loopback type not supported |
|
Mac Address Not Supported By Payload |
|
No such interface |
|
Node Name Configuration Failed |
|
Not a Sonet interface |
|
Object Already In Use |
|
Object Not Provisioned |
|
Object Not Supported |
|
Operation Not Supported On EC1 Interface |
|
Operation not supported by this card |
|
Optical Channel Not Provisioned |
|
Path Width Not Supported |
|
Path loopback already exists |
|
Reach Not Supported With Current Configuration |
|
SNTP Configuration Failed |
|
SSM not supported on SDH |
|
STS Path Not Provisioned |
|
Synchronization Configuration Not Available |
|
Synchronization Status Messaging(SSM) Not Supported On EC1 Interface |
|
Synchronization Status Messaging(SSM) Not Supported On SDH |
|
Synchronization::Sync not available |
|
System Timing Not Applicable For This Platform |
|
Trace Not Applicable On This Card |
|
Used Frame Format Does Not Support Synchronization Status Messaging (SSM) |
|
VLAN Not Provisioned |
|
VT Path Not Provisioned |
|
Wavelength Not Supported With Current Configuration |
|
Wrong Facility Type |
|
Wrong Interface Type |
|
bind failed for Sonet gen |
|
getActiveRefSource failed |
|
getRefSources failed |
Table 3-45: SDLD Error
| SDLD Error Message |
|---|
|
Duplex Unit Locked |
Table 3-46: SDNA Errors
| SDNA Error Messages |
|---|
|
Active TCC Not Ready |
|
Standby TCC Not Ready |
Table 3-47: SDNR Error
| SDNR Error Message |
|---|
|
Data Not Ready |
Table 3-48: SNCC Errors
| SNCC Error Messages |
|---|
|
Cross-connection does not exist |
|
Path Roll Does Not Exist |
|
Replace This Message When A SNCC message is needed |
Table 3-49: SNCN Errors
| SNCN Error Messages |
|---|
|
Bad Quality |
|
Cannot Switch To Bad Reference |
|
Cannot Switch To Inferior Reference Source |
|
Command Not Implemented |
|
Cross-Connection Type Not Supported In TL1 |
|
Invalid Clock Source |
|
Requested Direction Not Supported |
|
STS Rate Change Not Supported |
|
Sync Switch Operation Failed, Reference In OOS |
Table 3-50: SNNS Error
| SNNS Error Message |
|---|
|
Reference Not From Optical Card |
Table 3-51: SNOS Errors
| SNOS Error Messages |
|---|
|
Cannot Change Card Wavelength With Port(s) Not In OOS,DSBLD State |
|
Cannot Change Payload With Port(s) Not In OOS State |
|
Cannot Change Payload With Port(s) Not In OOS-MA,DSBLD State |
|
Cannot Change Termination Mode With Port(s) Not In OOS State |
Table 3-52: SNPR Errors
| SNPR Error Messages |
|---|
|
Cannot Get Role Of Port |
|
Get Port Role Failed |
Table 3-53: SNVS Errors
| SNVS Error Messages |
|---|
|
Already Switched To Internal Reference Source |
|
BLSR East Operation Already Set |
|
BLSR West Operation Already Set |
|
CCAT Cross Connect Exists |
|
Cannot Change BITS Configuration With Current State/Status |
|
Cannot Change Configuration When Trunk Ports (or Peer Ports, if any) Are Not In OOS,DSBLD State |
|
Cannot Change Parameter With Current State/Status |
|
Cannot Change Payload For Port Used For Overhead |
|
Cannot Change Payload When Port(s) Are Used As A Clock Source |
|
Cannot Change Port State With Current State/Status |
|
Cannot Change Revertive Behavior When A Protection Switch Is Active |
|
Cannot Change Synchronization Configuration With Current State/Status |
|
Cannot Change Termination Mode When Port(s) Are DCC Enabled |
|
Cannot Change Termination Mode When Port(s) Are Used As a Clock Source |
|
Cannot Change Termination Mode With Trace Enabled |
|
Cannot Change Timing Reference With Current State/Status |
|
Cannot Change or Delete Payload When Port(s) Are DCC Enabled |
|
Cannot Configure Port When J0 Section Trace Enabled |
|
Cannot Delete Port Involved In Loopback |
|
Cannot END An AUTO Roll |
|
Cannot Edit Facility When Not OOS State |
|
Cannot Operate Loopback In Current Cross-connection State |
|
Cannot Operate Loopback In Current State |
|
Cannot Provision Regeneration Group When A Protection Switch Operation Is Present |
|
Cannot Provision Regeneration Group When Equipment Has Different FEC Settings |
|
Cannot Provision Regeneration Group When Equipment Has Different G.709 Settings |
|
Connection Already In Roll |
|
Cross-Connect Exists |
|
Facility Not Part Of BLSR |
|
Invalid AINS Soak Time |
|
Invalid Admin State |
|
Invalid BLSR Element |
|
Invalid Clock Source |
|
Invalid Equipment State |
|
Invalid Transponder Provisioning |
|
Loopback Already In Progress |
|
Loopback Not In Progress |
|
No Switch In Progress |
|
No Valid Roll Signal |
|
No loopback in progress |
|
Operation Can Not Be Completed. NE Is In Version UP State |
|
Protection Group Does Not Exist |
|
Protection Unit Active |
|
Provisioning Not Allowed On Protecting Card |
|
Roll Condition Does Not Exist |
|
Roll is not controlled by TL1 |
|
Status, Not in Valid State |
|
Unable To Complete Roll |
|
VCG Already Created |
|
Working Unit Already Active |
|
Working Unit Already Standby |
Table 3-54: SOSE Error
| SOSE Error Message |
|---|
|
Unrecognized Message Type |
Table 3-55: SPFA Errors
| SPFA Error Messages |
|---|
|
Cannot Get Current Card Status |
|
Protection Unit Failed Or Missing |
|
Status, Protection Unit Failed or Missing |
Table 3-56: SPLD Errors
| SPLD Error Messages |
|---|
|
Cannot Create 1+1 Protection Group |
|
Cannot Delete Equipment |
|
Equipment In Use |
|
FTP Task Is Busy |
|
Facility Is Busy |
|
Protection Unit Locked |
Table 3-57: SRAC Errors
| SRAC Error Messages |
|---|
|
Invalid Connection Type |
|
Requested Access Configuration is Invalid |
Table 3-58: SRCN Errors
| SRCN Error Messages |
|---|
|
Already In Requested Mode |
|
Area already exists on lan interface |
|
Cannot use backbone area, lan active |
|
Protection Group Already Exists |
|
Requested Condition Already Exists |
Table 3-59: SROF Errors
| SROF Error Messages |
|---|
|
1+1 Protection Group Not Found |
|
1WAYMON not supported |
|
2F BLSR Pool Not Available |
|
4F BLSR EastProtect Pool Is Not Available |
|
4F BLSR Pool Not Available |
|
4F BLSR WestProtect Pool Is Not Available |
|
ADM Peer Group Does Not Exist |
|
ADM Peer Group Is Provisioned |
|
AID Does Not Match With Requested Roll Type |
|
AID Listing Not Allowed |
|
ALL Rolls Failed |
|
ALS Mode Does Not Allow Laser Restart |
|
APC Not Applicable |
|
APC System Is Busy |
|
APC System Is Not Enabled |
|
Active Flash Not Ready |
|
Alarm Type Not Found |
|
Alarm type In Use |
|
All DCCs In Use |
|
All Link Terminations On Port Must Terminate On Same Remote Node |
|
All Rolls Failed to Cancel |
|
All Rolls Failed to Complete |
|
All Rolls Failed to Edit |
|
BFDL Mode Requires ESF Framing |
|
BLSR In Use |
|
BLSR Pool Not Available |
|
BLSR Protect STS Path List Is Empty |
|
BLSR Spans Are Not Locked |
|
Bridge And Roll Not Supported On Roll From And/Or Roll To |
|
CKTID Does Not Match |
|
CMDMDE Must Be FRCD To Create Protection Group With Pre-provisioned Cards |
|
Can Not Get IOS Config Source Origin |
|
Cannot Access 1+1 Line |
|
Cannot Access 1+1 Protected Line |
|
Cannot Access 2 Fiber BLSR |
|
Cannot Access 4 Fiber BLSR East Protection |
|
Cannot Access 4 Fiber BLSR West Protection |
|
Cannot Access 4F BLSR |
|
Cannot Access Alarm Log |
|
Cannot Access Audit Log |
|
Cannot Access BLSR 2-Wire Line |
|
Cannot Access BLSR |
|
Cannot Access Cross-Connection |
|
Cannot Access DCC |
|
Cannot Access Facility |
|
Cannot Access PM Mode |
|
Cannot Access Performance Monitoring Statistics |
|
Cannot Access Protected Equipment |
|
Cannot Access Protection Group Information |
|
Cannot Access Protection Group Name |
|
Cannot Access Protection Group Reversion Information |
|
Cannot Access Reversion Information |
|
Cannot Access STS |
|
Cannot Access TAP |
|
Cannot Access TL1 Craft Session |
|
Cannot Access Unprotected Line |
|
Cannot Access VT |
|
Cannot Add Equipment |
|
Cannot Change Card Mode In SWDL State |
|
Cannot Change Configuration With Port Having Connection |
|
Cannot Change Entity In A Protection Group |
|
Cannot Change Equipment Type |
|
Cannot Change Ethernet IP With DHCP Provisioned |
|
Cannot Change Ethernet IP With OSPF Provisioned |
|
Cannot Change Parameter When User Switch Exists |
|
Cannot Change G.709 Setting On This Card |
|
Cannot Change G.709 Setting With Port Having Connection |
|
Cannot Change Payload When Regeneration Group Exist |
|
Cannot Change Threshold Values On Protect Card |
|
Cannot Change Timing Reference When User Switch Exists |
|
Cannot Change XTC Protection Group |
|
Cannot Clear Performance Monitoring Statistics On Protect Card |
|
Cannot Configure SYNC |
|
Cannot Create Cross-Connection Between Incompatible Interfaces |
|
Cannot Create OCHNC With Invalid DWDM Network Type |
|
Cannot Create Protection Group |
|
Cannot Create TAP On Last VT |
|
Cannot Create TAP |
|
Cannot Create Y-cable Protection |
|
Cannot Delete CCAT Cross-Connection In Forced Mode |
|
Cannot Delete Cross-Connection |
|
Cannot Delete Last Drop |
|
Cannot Delete Link Termination Having Active Circuit |
|
Cannot Delete Protected Equipment |
|
Cannot Delete Protection Group |
|
Cannot Delete System Defined Alarm Type |
|
Cannot Delete VCAT Group When Members Are In Group |
|
Cannot Delete VCAT Group |
|
Cannot Delete VCAT Member When It Is In Group |
|
Cannot Delete VCG Member In Current State |
|
Cannot Disable DWRAP With FEC Enabled |
|
Cannot Disable DWRAP With GCC Enabled |
|
Cannot Disable DWRAP. Orderwire Circuit Exists |
|
Cannot Disable DWRAP. Y-Cable Protection Exists |
|
Cannot Edit Ethernet IP |
|
Cannot Edit STS |
|
Cannot Enable DWRAP With DCC Enabled |
|
Cannot Enable FEC When G.709 Is Disabled |
|
Cannot Enable FEC With DWRAP Disabled |
|
Cannot Modify Protect Card |
|
Cannot Operate Terminal Loopback With AISONLPBK Enabled |
|
Cannot Perform ACO |
|
Cannot Provision Equipment |
|
Cannot Provision Filler Equipment |
|
Cannot Provision Protection Equipment |
|
Cannot Retrieve Performance Monitoring Statistics From Protect Card |
|
Cannot Retrieve Threshold Values From Protect Card |
|
Cannot Roll Hairpin Connection |
|
Cannot Set ALS Mode |
|
Cannot Set Bidirectional Protection Group |
|
Cannot Set DCC When Digital Wrapper Is Enabled |
|
Cannot Set GCC When DWRAP Is Disabled |
|
Cannot Set GCCRATE With GCC Disabled |
|
Cannot Set GFP Buffer With AutoThresholdGfpBuf On |
|
Cannot Set Linkcredits With AutoDetection On |
|
Cannot Set Loopback In Current Mode |
|
Cannot Set NodeID |
|
Cannot Set Payload Type |
|
Cannot Set Protection Group Name |
|
Cannot Set RETIME, Port In Use |
|
Cannot Set ROLE When WDM Is Disabled |
|
Cannot Set RingID |
|
Cannot Set Span Revertive Mode Unless 4-Fiber Ring |
|
Cannot Set Span Revertive Time In Non-revertive Mode |
|
Cannot Set Span Revertive Time Unless 4-Fiber Ring |
|
Cannot Set Termination Mode |
|
Cannot Set Wave Length |
|
Cannot Setup Connection With Port In OOS-MT |
|
Cannot Switch For Specified Connection Type |
|
Cannot Switch For Specified Path |
|
Cannot Update AISONLPBK When Loopback In Progress |
|
Cannot Update Synchronization Reference List |
|
Cannot force 1way destination roll |
|
Cannot modify cross-connect right now |
|
Card Mode Provisioning Failed |
|
Clear PM Not Supported |
|
Command Not Supported |
|
Connection In Loopback |
|
Connection In Roll |
|
Connection In Test Access |
|
Connection In Topology Upgrade |
|
Connection Is Already In Roll |
|
Connection Type Error |
|
Control Channel In Use |
|
Could Not Delete Protection |
|
Could not provision area |
|
Cross-Connection Creation Failed |
|
Cross-Connection Does Not Exist |
|
Cross-connection Was Not Found |
|
Cross-connection deletion failed |
|
DCC Does Not Exist |
|
DCC In Use |
|
DCC Not In Use |
|
DCC Termination Is Required to Set OSPF |
|
DWRAP Not Enabled |
|
Data Link Using TE Link |
|
Data Not Available |
|
Database Is Busy |
|
Distance Extension And Directional Mode Are Not Compatible |
|
Duplicate Alarm Type Create Attempted |
|
Duplicate FTP Server Create Attempted |
|
Duplicate IP Address Route |
|
Duplicate Remote Link Termination Information |
|
Duplicate Remote TE Link |
|
Duplicate Tunnel Create Attempted |
|
Duplicate VLAN Create Attempted |
|
East And West Ports Must Have Dcc Terminations |
|
Element Not Found |
|
Element not available |
|
End Facilities Are Using Different Wavelength |
|
End Facilities Do Not Have An Internal Path |
|
Equipment Does Not Match Request |
|
Equipment Does Not Support 8B10B Montypes |
|
Equipment Does Not Support Cross-connection Loopback |
|
Equipment Is Double Slot Sized |
|
Equipment Provisioning Failed |
|
Ethernet IP And Default Router IP Subnets Are Different |
|
Exceed Max Matrix Port Allowed For VT1 Path |
|
Exceed Max Matrix Port Allowed For VT2 Path |
|
Expected Trace Size Exceeds Trace Format Limit |
|
FTP Server Not Found |
|
Facilities Are Not On Boundary |
|
Facilities Belong To Different Node Sides |
|
Facilities Must Be On Different Node Sides |
|
Facility Does Not Support Laser Restart |
|
Facility Has Unknown Node Side |
|
Facility Not Part Of Appropriate BLSR |
|
Facility Not Protected |
|
Fail To Add RTO |
|
Flash Is Busy |
|
Force To Primary Not Allowed |
|
Frame Format Not Applicable With Current Configuration |
|
Generation 1 Does Not Support Given Quality Of RES |
|
Generic IOS config upload failure message |
|
Get IOR Failed |
|
Has Valid Roll Signal Already |
|
Hello Dead Less Than 3X Hello |
|
Hello Dead Max Less Than Max |
|
Hello Dead Max Less Than Min |
|
Hello Dead Max Too Large |
|
Hello Dead Min Less Than Min |
|
Hello Dead Min Too Small |
|
Hello Dead Out Of Range |
|
Hello Max Less Than Min |
|
Hello Max Too Large |
|
Hello Min Too Small |
|
Hello Out Of Range |
|
Host Not In IP Address Format |
|
IPPM Not Supported By Equipment Type |
|
Impedance Not Applicable With Current Configuration |
|
Insufficient Path Width For Cross-Connection |
|
Insufficient Path Width For Test Access |
|
Insufficient Path Width on Roll Destination |
|
Interlink Port Does Not Exist |
|
Internal Database Error |
|
Internal Exercise Failure |
|
Internal Facility Type Failure |
|
Invalid AID |
|
Invalid ALS Recovery Interval |
|
Invalid ALS Recovery Pulse Width |
|
Invalid BLSR DRI Drop |
|
Invalid Broadcast Remote IP Address |
|
Invalid Class A Remote IP Address |
|
Invalid Class B Remote IP Address |
|
Invalid Class C Remote IP Address |
|
Invalid Control Type (CONTTYPE) For AID |
|
Invalid Cross-Connect Type For VCG |
|
Invalid Cross-Connection Path |
|
Invalid Cross-Connection Type (CRSTYPE) |
|
Invalid Cross-Connection Type For Drops |
|
Invalid Drop Path |
|
Invalid Local Node ID |
|
Invalid Local Port |
|
Invalid Loopback Provision |
|
Invalid Operation For Connection Type |
|
Invalid Operation For Specified Path |
|
Invalid Path |
|
Invalid Payload For LMP Data Link |
|
Invalid Protection Group |
|
Invalid Protection Switch Operation |
|
Invalid Provisioning For Current Configuration |
|
Invalid RMODE |
|
Invalid Reference Source for Timing |
|
Invalid Remote Data Link ID |
|
Invalid Remote Network Element |
|
Invalid Remote TE Link ID |
|
Invalid SYNC entity |
|
Invalid State When Loopback Present |
|
Invalid Subnet Mask |
|
Invalid Synchronization Source |
|
Invalid Path Protection Path |
|
Invalid Username/Password |
|
Invalid WDMANS PPMESH Parameter |
|
Invalid type for this Cross-connection |
|
Is Not 1+1 Element Type |
|
J0 Section Trace Level Not Supported By 10GE Payload Type |
|
LMP Data Link Using Port |
|
Laser Was Not Shutdown.Cannot Restart Laser |
|
Line Code Not Applicable With Current Configuration |
|
Link Does Not Exist |
|
Link Termination Does Not Exist |
|
Link Termination Id Already In Use |
|
Local And Remote IP Addresses the Same |
|
Location Incompatible With Loopback Type |
|
Loopback Not Allowed On Drop Path |
|
Loopback Type Does Not Match |
|
MIC Cards Cannot Be Reset |
|
Maximum Control Controls Provisioned |
|
Maximum DIAG Crossconnect Limit Reached |
|
Maximum Data Links For TE Link Provisioned |
|
Maximum Data Links Provisioned |
|
Maximum Drop Limit Reached |
|
Maximum FTP server Creation Limit Exceeded |
|
Maximum Link Terminations On Port Reached |
|
Maximum TE Links Provisioned |
|
Maximum Tunnel Creation Limit Exceeded |
|
Maximum User Limit Reached |
|
Maximum UserDefined Alarm Type Limit |
|
Maximum VT Cross Connection Limit Reached |
|
Multi-Shelf Mode Not Supported On This Equipment |
|
Multi-Shelf Mode Not Supported On This Platform |
|
Multi-Shelf disable not allowed |
|
No Path To Regulate |
|
No Start-Up IOS Config |
|
No clock and data copy information from Line cards and SSXC cards |
|
Node::General not available |
|
Node::NetworkConfig not available |
|
Non Revertive Mode Does Not Allow to Set RVTM |
|
Not Compatible With Protect |
|
Not Enough Path Width For TACC |
|
Number of Drops Exceed Allowable |
|
OCH Client Connection Already Exist |
|
OCH Client Connection Does Not Exist |
|
OCHNC Connection Does Not Exist |
|
One Plus One Line pool not available |
|
Operate Alarm Cutoff Failed |
|
Operation Not Suported By XC Card |
|
Operation Not Supported On Port |
|
Operation Not Supported |
|
Operation not Valid for Connection Type |
|
Operation not Valid for Path Specified |
|
OspfTopology::OSPFTopo not available |
|
PM Not Supported For Specified Path |
|
Parameter Not Supported When DWRAP Is Enabled |
|
Path Already In Use |
|
Path Specified Is Not Valid |
|
Path Used For Test Access |
|
Payload Provisioning Failed |
|
Payload Type Does Not Support Trace |
|
Peer Equipment Attributes Do Not Match |
|
Peer Equipment Type Does Not Match |
|
Peer Facility Has Loopback |
|
Peer Facility Is IS |
|
Peer Facility Not In OOS-MT |
|
Peer Payload Type Does Not Match |
|
Peer Termination Mode Does Not Match |
|
Platform Does Not Support Given AIS Threshold Value |
|
Platform Does Not Support Given Frame-Format Value |
|
Platform Does Not Support Given Line Code Value |
|
Platform Does Not Support Given Quality Of RES |
|
Pool Does Not Exist |
|
Pool not available |
|
Port In Use |
|
Port Type Already Provisioned |
|
Port Type Mismatch |
|
Port Type Not Provisioned |
|
Protect Port Active |
|
Protection Group Busy |
|
Protection Group Does Not Exist |
|
Protection Switch In Progress |
|
Protection Switching Failed |
|
Protection Type Mismatch |
|
Protection Type Not Compatible With Facility |
|
Provisioning Rules Failed |
|
Quality Of Clock Reference Not Applicable For This Platform Or Selected System Timing |
|
RMON Threshold Does Not Exist |
|
ROLL TO Path Is Already In The Cross-connection |
|
Regeneration Group Already Exist |
|
Regeneration Group Does Not Exist |
|
Remote IP Address Cannot Be Class D Or E |
|
Remote IP Address Cannot Equal The Node IP Address |
|
Remote IP Address Cannot Equal The Node Mask |
|
Remote IP Address Has Invalid Host Portion |
|
Remote IP Address Is All Ones |
|
Remote IP Address On Internal Net |
|
Remote IP Address On Local Net |
|
Requested Operation Failed |
|
Requested Tap Busy |
|
Revertive Mode Not Supported |
|
Ring Reversion Failed |
|
Roll Failed |
|
Roll To Path Not Aligned |
|
SDBER Out Of Range |
|
SDCC creation failed |
|
SFBER Out Of Range |
|
SSet PRG Reversion Failed |
|
STS Does Not Exist |
|
STS Does Not Have TAP |
|
STS Path Width Does Not Match |
|
STS Rates Do Not Match |
|
SaBit Not Applicable With Current Configuration |
|
Section Termination Mode Not Supported |
|
Security::General not available |
|
Set PRG Bidirectional Failed |
|
Set PRG Name Failed |
|
Side Not Applicable To WDMANS Application |
|
Slot Does Not Support New Equipment Type |
|
Software Activation Failed |
|
Software Download Failed |
|
Software Error |
|
Software Reversion Failed |
|
Span Reversion Failed |
|
Specified Operation Is Not Valid |
|
Standby Flash Not Ready |
|
Sync Reference List Update Failed |
|
Synchronization Status Messaging (SSM) Not Supported In Current Configuration |
|
Synchronization/Timing Parameters Not Supported With DWRAP Enabled |
|
TAP connected |
|
TARP Origination Is Disabled |
|
TCC Type Does Not Support Given Framing Type |
|
TE Link In Use |
|
TE Link Using Control Channel |
|
TID exists in TADRMAP |
|
TL1 Cannot Roll Connections In A Port Group |
|
TTI Trace Not Allowed With G709 Disabled |
|
Tap Not Provisioned |
|
Test Access Active |
|
Test Access Not Supported On Card |
|
The Maximum number of TID-Address pairs has been reached |
|
This Timer Not Applicable to Standard 1+1 |
|
Trace Format Not Supported By J0 Section Trace |
|
Trace Format Not Supported By TTI Section Trace |
|
Trace Format Unsupported |
|
Trace Message Size Exceeds Trace Format Limit |
|
Trace Mode Incompatible With Termination Mode |
|
Trace Mode Not Supported |
|
Trap Destination Already Exists |
|
Trap Destination Does Not Exist |
|
Trap Table Full |
|
Tunnel Not Found |
|
Path Protection Needed To Change Revertive Behavior |
|
Path Protection Selector Not Allowed On Non-Optical Ports |
|
Unable To Cancel Roll |
|
Unknown Internal Error |
|
Unprotected Line pool not available |
|
Unprovisioning Rules Failed |
|
Unsupported BLSR STS Path Operation |
|
Unsupported Command Type |
|
Unsupported Element Type |
|
VCG Does Not Exist |
|
VLAN Already In Use |
|
VLAN Not Applicable |
|
VT Cross-Connection Does Not Exist |
|
VT Does Not Exist |
|
VT Does Not Have TAP |
|
VT Path Width Does Not Match |
|
WDMANS Not Regulated |
|
WDMANS System Is Busy |
|
Wavelength Value Not Supported |
|
Working/Peer Card In Use |
|
Wrong Interface Type |
|
XC Card Does Not Support VT Cross-Connection |
|
XC Card Not Present |
|
XCVXL Card Not Present |
|
Y-Cable Protection Does Not Exist |
Table 3-60: SRQN Errors
| SRQN Error Messages |
|---|
|
Admssm Not Allowed When SSM Enabled |
|
BLSR Creation Failed |
|
BLSR Deletion Failed |
|
BLSR Does Not Exist |
|
BLSR Editing Failed |
|
Cannot Create Automatic Links |
|
Cannot Edit ADMSSM On Protect Port |
|
Cannot Edit HIWRMK While Port Is In Transponder Mode |
|
Cannot Edit LOWRMK While Port Is In Transponder Mode |
|
Cannot Edit MFS While Port Is In Transponder Mode |
|
Cannot Edit SENDDUS On Protect Port |
|
Cannot Edit SYNCMSG On Protect Port |
|
DCC Not Allowed In SDH Mode |
|
DCC Not Allowed On Protect Port |
|
DCC not enabled |
|
Data Access Request Failed |
|
Invalid Mode For Current Configuration |
|
Invalid Request |
|
OSC Group Already Exists |
|
OSC Group Does Not Exist |
|
Path loopback already exists |
|
Protect Card Does Not Support Electrical Protection |
|
Protect Card Does Not Support Protection Type |
|
SDH Not Allowed On Protect Port |
|
SDH Not Allowed With DCC |
|
SDH Not Allowed With SENDDUS |
|
SDH Not Allowed With SYNCMSG |
|
SDH Not Allowed |
|
SECURITY CANNOT BE CHANGED |
|
SENDDUS Not Allowed With SDH Mode |
|
STS Cross-Connection Does Not Exist |
|
SYNCMSG Not Allowed With SDH Mode |
|
Sync Status Messaging(SSM) Not Allowed With SDH Mode |
|
TCC CANNOT SUPPORT FRONT-END PORT |
|
VT Cross-Connection Does Not Exist |
Table 3-61: SRTN Error
| SRTN Error Message |
|---|
|
TAP Not Found |
Table 3-62: SSRD Errors
| SSRD Error Messages |
|---|
|
Manual Switch Cannot Override Forced Switch |
|
Switch Request Denied |
Table 3-63: SSRE Errors
| SSRE Error Messages |
|---|
|
GNE: ENE Connection Closed |
|
GNE: System Resources Exceeded - FD |
|
GNE: System Resources Exceeded - Lock |
|
GNE: System Resources Exceeded - Thread |
|
Memory Resources Exceeded |
|
Memory resource denial |
Table 3-64: SWFA Errors
| SWFA Error Messages |
|---|
|
Status, Working Unit Failed or Missing |
|
Working Unit Failed Or Missing |
Table 3-65: SWLD Error
| SWLD Error Message |
|---|
|
Working Unit Locked |
Echo
In order to improve Telnet functionality for automated systems, the echo function has been turned off in ONS 15454 Release 3.0 and later. This change is transparent to users running standard UNIX-compliant Telnet clients; however, PC users might need to change their client setup to enable "local echo." This is normally accomplished by a drop-down list or a preference attribute.
To test the local echo on your PC client, use the RTRV-HDR command. If you receive a response but no data, set the local echo to ON. Cisco recommends that you close any windows containing sensitive information after exiting a TL1 session.