General: RTSP live monitoring sessions fail when using CUBE

From DocWiki

Revision as of 17:08, 27 January 2012 by Dosproul (Talk | contribs)
Jump to: navigation, search

RTSP live monitoring sessions fail when using CUBE

Problem Summary When using a mixed load in a CUBE deployment, multiple RTSP live monitoring sessions failed (RTSP packets were dropped). Recordings may also sound very choppy on playback.
Error Message None.
Possible Cause CUBE may be using a lower Ethernet cable connection (for example, 100 MB connection) instead of the suggested 1 GB Ethernet cable connection. Under a heavy load, this connection may cause multiple IP packets to drop.
Recommended Action If your CUBE deployment is running heavy loads, verify that the Ethernet cable connecting CUBE to the switch is 1 GB.
Release Release 8.5(3), Release 8.5(4).
Associated CDETS # None.