RTSP live monitoring sessions fail when using CUBE
| Problem Summary | When using a mixed load in a CUBE deployment, multiple RTSP live monitoring sessions failed (RTSP packets were dropped). Recordings may also sound very choppy on playback. |
|---|---|
| Error Message | None. |
| Possible Cause | CUBE may be using a lower Ethernet cable connection (for example, 100 MB connection) instead of the suggested 1 GB Ethernet cable connection. Under a heavy load, this connection may cause multiple IP packets to drop. |
| Recommended Action | If your CUBE deployment is running heavy loads, verify that the Ethernet cable connecting CUBE to the switch is 1 GB. |
| Release | Release 8.5(3), Release 8.5(4), Release 9.0(1). |