Question: What is the quickest way to start developing custom scripts.

Answer: Starting with CUE 3.2, we have introduced script editor in the CUE Administration GUI - System -> Scripts -> New.

http://www.cisco.com/en/US/docs/voice_ip_comm/unity_exp/rel3_2/administrator/gui/edit_exp.html


For all versions, here is a quick start guide for creating Custom Scripts:

http://www.cisco.com/en/US/partner/products/sw/voicesw/ps5520/products_tech_note09186a008041d950.shtml




Question: Where can I download editor installer for my CUE version and sample scripts.

Answer:

Please download the appropriate CUE Custom Script Editor from Cisco CCO web site at:

http://tools.cisco.com/support/downloads/go/Redirect.x?mdfid=278535672

Choose the appropriate CUE version that you are running.

Once you are in the appropriate CUE version software page, download the editor and sample scripts.

- Click on “Utilities” link to download the CUE Editor and install it on a windows PC.

- Click on “Sample Auto-Attendant Scripts” to download the sample scripts.




Question: How can I capture debug traces/logs when my script is not working as designed.

Answer:

Method-1:

1. Make sure the system is idle.

2. Run "clear trace" on CUE.

3. Run "show trace buffer tail" on CUE.

4. Make the simplest call to demonstrate your problem.

5. Wait until the logs stop scrolling ... Might take 3 to 5 minutes.

6. Press CTRL-C to exit.

7. Send us the logs for the failure case.


Method-2: You will need a FTP server.

1. Make sure the system is idle.

2. Make the simplest call to demonstrate your problem.

3. Run “log trace buffer save” on CUE.

4. Run “copy log atrace_save.log url ftp://x.x.x.x/....”

5. Send us this file.