Cisco Nexus 7000 Series NX-OS Troubleshooting Guide -- Troubleshooting vPCs
From DocWiki
m |
|||
(One intermediate revision not shown) | |||
Line 2: | Line 2: | ||
This article describes how to do basic troubleshooting of virtual Port Channel(vPC) problems on a Cisco Nexus 7000 NX-OS device. | This article describes how to do basic troubleshooting of virtual Port Channel(vPC) problems on a Cisco Nexus 7000 NX-OS device. | ||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
Line 28: | Line 7: | ||
|aling="center"|'''Guide Contents''' | |aling="center"|'''Guide Contents''' | ||
|- | |- | ||
- | |[[Cisco Nexus 7000 Series NX-OS Troubleshooting Guide -- Troubleshooting Overview|Troubleshooting Overview]]<br>[[Cisco Nexus 7000 Series NX-OS Troubleshooting Guide -- Troubleshooting Installs, Upgrades, and Reboots|Troubleshooting Installs, Upgrades, and Reboots]]<br>[[Cisco Nexus 7000 Series NX-OS Troubleshooting Guide -- Troubleshooting Licensing|Troubleshooting Licensing]]<br>[[Cisco Nexus 7000 Series NX-OS Troubleshooting Guide -- Troubleshooting VDCs|Troubleshooting VDCs]]<br>[[Cisco Nexus 7000 Series NX-OS Troubleshooting Guide -- Troubleshooting CFS|Troubleshooting CFS]]<br>[[Cisco Nexus 7000 Series NX-OS Troubleshooting Guide -- Troubleshooting Ports|Troubleshooting Ports]]<br>''Troubleshooting vPCs {this section}''<br>[[Cisco Nexus 7000 Series NX-OS Troubleshooting Guide -- Troubleshooting VLANs|Troubleshooting VLANs]]<br>[[Cisco Nexus 7000 Series NX-OS Troubleshooting Guide -- Troubleshooting STP|Troubleshooting STP]]<br>[[Cisco Nexus 7000 Series NX-OS Troubleshooting Guide -- Troubleshooting Routing|Troubleshooting Routing]]<br>[[Cisco Nexus 7000 Series NX-OS Troubleshooting Guide -- Troubleshooting Unicast Traffic|Troubleshooting Unicast Traffic]]<br>[[Cisco Nexus 7000 Series NX-OS Troubleshooting Guide -- Troubleshooting WCCP|Troubleshooting WCCP]]<br>[[Cisco Nexus 7000 Series NX-OS Troubleshooting Guide -- Troubleshooting Memory|Troubleshooting Memory]]<br>[[Cisco Nexus 7000 Series NX-OS Troubleshooting Guide -- Troubleshooting Packet Flow Issues|Troubleshooting Packet Flow Issues]]<br>[[Cisco Nexus 7000 Series NX-OS Troubleshooting Guide -- Before Contacting Technical Support|Before Contacting Technical Support]]<br>[[Cisco Nexus 7000 Series NX-OS Troubleshooting Guide -- Troubleshooting Tools and Methodology|Troubleshooting Tools and Methodology]] | + | |[[Cisco Nexus 7000 Series NX-OS Troubleshooting Guide -- Troubleshooting Overview|Troubleshooting Overview]]<br>[[Cisco Nexus 7000 Series NX-OS Troubleshooting Guide -- Troubleshooting Installs, Upgrades, and Reboots|Troubleshooting Installs, Upgrades, and Reboots]]<br>[[Cisco Nexus 7000 Series NX-OS Troubleshooting Guide -- Troubleshooting Licensing|Troubleshooting Licensing]]<br>[[Cisco Nexus 7000 Series NX-OS Troubleshooting Guide -- Troubleshooting VDCs|Troubleshooting VDCs]]<br>[[Cisco Nexus 7000 Series NX-OS Troubleshooting Guide -- Troubleshooting CFS|Troubleshooting CFS]]<br>[[Cisco Nexus 7000 Series NX-OS Troubleshooting Guide -- Troubleshooting Ports|Troubleshooting Ports]]<br>''Troubleshooting vPCs {this section}''<br>[[Cisco Nexus 7000 Series NX-OS Troubleshooting Guide -- Troubleshooting VLANs|Troubleshooting VLANs]]<br>[[Cisco Nexus 7000 Series NX-OS Troubleshooting Guide -- Troubleshooting STP|Troubleshooting STP]]<br>[[Cisco Nexus 7000 Series NX-OS Troubleshooting Guide -- Troubleshooting Routing|Troubleshooting Routing]]<br>[[Cisco Nexus 7000 Series NX-OS Troubleshooting Guide -- Troubleshooting Unicast Traffic|Troubleshooting Unicast Traffic]]<br>[[Cisco Nexus 7000 Series NX-OS Troubleshooting Guide -- Troubleshooting WCCP|Troubleshooting WCCP]]<br>[[Cisco Nexus 7000 Series NX-OS Troubleshooting Guide -- Troubleshooting Memory|Troubleshooting Memory]]<br>[[Cisco Nexus 7000 Series NX-OS Troubleshooting Guide -- Troubleshooting FCoE|Troubleshooting FCoE]]<br>[[Cisco Nexus 7000 Series NX-OS Troubleshooting Guide -- Troubleshooting Packet Flow Issues|Troubleshooting Packet Flow Issues]]<br>[[Cisco Nexus 7000 Series NX-OS Troubleshooting Guide -- Before Contacting Technical Support|Before Contacting Technical Support]]<br>[[Cisco Nexus 7000 Series NX-OS Troubleshooting Guide -- Troubleshooting Tools and Methodology|Troubleshooting Tools and Methodology]] |
|} | |} | ||
Line 42: | Line 21: | ||
A vPC allows links that are physically connected to two different Cisco Nexus 7000 Series devices to appear as a single port channel by a third device. | A vPC allows links that are physically connected to two different Cisco Nexus 7000 Series devices to appear as a single port channel by a third device. | ||
- | See the [http://www.cisco.com/en/US/docs/switches/datacenter/sw/4_1/nx-os/interfaces/configuration/guide/if_vPC.html Configuring vPC chapter] in the [http://www.cisco.com/en/US/docs/switches/datacenter/sw/ | + | See the [http://www.cisco.com/en/US/docs/switches/datacenter/sw/4_1/nx-os/interfaces/configuration/guide/if_vPC.html Configuring vPC chapter] in the [http://www.cisco.com/en/US/docs/switches/datacenter/sw/6_x/nx-os/interfaces/configuration/guide/if_cli.html Cisco Nexus 7000 Series NX-OS Interfaces Configuration Guide] for more information on vPCs. |
== Initial Troubleshooting Checklist == | == Initial Troubleshooting Checklist == | ||
Line 332: | Line 311: | ||
The following links contain further information on this topic from Cisco.com: | The following links contain further information on this topic from Cisco.com: | ||
- | + | [http://www.cisco.com/en/US/docs/switches/datacenter/sw/6_x/nx-os/interfaces/configuration/guide/if_vPC.html Configuring vPCs (Cisco Nexus 7000 Series Interfaces Configuration Guide)] | |
- | + | ||
- | [http://www.cisco.com/en/US/docs/switches/datacenter/sw/ | + | |
[http://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps9670/configuration_guide_c07-543563.html Nexus 5000 Virtual PortChannel Quick Configuration Guide] | [http://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps9670/configuration_guide_c07-543563.html Nexus 5000 Virtual PortChannel Quick Configuration Guide] |
Latest revision as of 12:20, 9 December 2013
This article describes how to do basic troubleshooting of virtual Port Channel(vPC) problems on a Cisco Nexus 7000 NX-OS device.
Information About Troubleshooting vPCs
A vPC allows links that are physically connected to two different Cisco Nexus 7000 Series devices to appear as a single port channel by a third device.
See the Configuring vPC chapter in the Cisco Nexus 7000 Series NX-OS Interfaces Configuration Guide for more information on vPCs.
Initial Troubleshooting Checklist
Begin troubleshooting vPC issues by checking the following issues first:
Checklist | Check off |
---|---|
Verify that all vPC interfaces in a vPC domain are configured in the same virtual device context (VDC). | |
Verify that you have a separate vPC peer-link and peer-keepalive link infrastructure for each VDC deployed. | |
Is the vPC keepalive link mapped to a separate vrf? If not, it will be mapped to the management vrf by default. In this case, do you have a management switch connect to the management ports on both vPC peer devices? | |
Verify that the vPC peer-link is configured on a N7K-M132XP-12. It is recommended to have at least two N7K-M132XP-12 for redundancy. | |
Verify that both the source and destination IP addresses used for the peer-keepalive messages are reachable from the VRF associated with the vPC peer-keepalive link. | |
Verify that the peer-keepalive link is up or the vPC peer-link will not come up. | |
Verify that the vPC peer-link is configured as a Layer 2 Port Channel trunk which only allows vPC VLANs. | |
Verify that the vPC number that you assigned to the port channel that connects to the downstream device from the vPC peer device is identical on both vPC peer devices. | |
If you manually configured the system priority, verify that you assigned the same priority value on both vPC peer devices. | |
Check the show vpc consistency-parameters command to verify that both vPC peer devices have identical type-1 parameters. | |
Verify that the primary vPC is the primary STP root and the secondary vPC is the secondary STP root. |
Verifying vPCs Using the CLI
To verify vPCs using the CLI, follow these steps:
1. Use the show running-config vpc command to verify the vPC configuration.
2. Use the show vpc command to check the status of vPC.
3. Use the show vpc peer-keepalive command to check the status of the vPC peer-keepalive link.
4. Use the show vpc consistency-parameters command to verify that both the vPC peers have the identical type-1 parameters.
5. Use the show port-channel summary command toverify the members in the port channel are mapped to the vPC.
6. Use the show cfs status commands to verify that distribution over Ethernet is enabled.
7. If you enable STP, use the show spanning-tree command on both sides of the vPC peer link to verify that the following STP parameters are identical:
- BPDU Filter
- BPDU Guard
- Cost
- Link type
- Priority
- VLANs (PVRST+)
Received Type 1 Configuration Element Mismatch
You may have a problem where you cannot bring up a vPC link because of a type 1 configuration element mismatch.
Symptom | Possible Cause | Solution | |
---|---|---|---|
Received a type 1 configuration element mismatch. |
The vPC peer ports or membership ports do not have identical configurations. |
Use the show vpc consistency-parameters interface command to determine where the configuration mismatch occurs. |
Example: show vpc consistency-parameters Command Output
This example shows how to display the vPC consistency parameters on a port channel:
switch# show vpc consistency-parameters interface po 10 Legend: Type 1 : vPC will be suspended in case of mismatch Name Type Local Value Peer Value ------------- ---- ---------------------- ----------------------- STP Mode 1 Rapid-PVST Rapid-PVST STP Disabled 1 None None STP MST Region Name 1 "" "" STP MST Region Revision 1 0 0 STP MST Region Instance to 1 VLAN Mapping STP Loopguard 1 Disabled Disabled STP Bridge Assurance 1 Enabled Enabled STP Port Type 1 Normal Normal STP MST Simulate PVST 1 Enabled Enabled Allowed VLANs - 1-10,15-20,30,37,99 1-10,15-20,30,37,99
Cannot Enable the vPC Feature
You may receive an error when you enable the vPC feature.
Symptom | Possible Cause | Solution |
---|---|---|
Cannot enable the vPC feature. |
The hardware is incompatible with the vPC. |
Use the show module command to determine the hardware version of each N7K-M132XP-12 Ethernet module. The hardwere version must be 1.3 or later to enable the vPC feature. |
Example: show module Command Output
This example shows how to display the module hardware version:
switch# show module Mod Ports Module-Type Model Status --- ----- -------------------------------- ------------------ ------------ 2 32 10 Gbps Ethernet Module N7K-M132XP-12 ok 3 48 10/100/1000 Mbps Ethernet Module N7K-M148GT-11 ok 5 0 Supervisor module-1X N7K-SUP1 active * 6 0 Supervisor module-1X N7K-SUP1 ha-standby 10 32 10 Gbps Ethernet Module N7K-M132XP-12 ok Mod Sw Hw --- -------------- ------ 2 4.1(5) 1.2 3 4.1(5) 1.0 >>> Must be 1.3 or later.
vPC in Blocking State
vPC may be in the blocking state because of Bride Assurance (BA).
Symptom | Possible Cause | Solution |
---|---|---|
vPC is in blocking state. |
BPDU only sends on a single link of a port-channel. If BA dispute is detected, the entire vPC will be in the blocking state. |
Do not enable BA on vPC. |
VLANs on a vPC moved to suspend state
VLANs on a vPC may move to the suspend state.
Symptom | Possible Cause | Solution |
---|---|---|
VLANs on a vPC moved to suspend state. |
VLANs allowed on the vPC have not been allowed on the vPC peer=link. |
All VLANs allowed on a vPC must also be allowed on the vPC peer-link. Also, it is recommended that only vPC VLANs are allowed on the vPC peer-link. |
Hosts with an HSRP Gateway Cannot Access Beyond Their VLAN
When HSRP is enabled on both vPC peer devices on a VLAN and hosts on that VLAN set the HSRP as their gateway, they may not able to reach anything outside their own VLAN.
Symptom | Possible Cause | Solution |
---|---|---|
Hosts with an HSRP gateway cannot access beyond their VLAN. |
If the host gateway mac-address is mapped to the physical MAC address of any one of the vPC peer-devices, packets may get dropped due to the loop prevention mechanism in vPC. |
Map the host gateway's mac-address to the HSRP MAC address and not the physical MAC address of any one of the vPC peer-devices. Peer-gateway can be a workaround for this scenario. Please read the configuration guide for peer-gateway for further information before implementing it. |
Traffic Disrupted when the Primary vPC Device Goes Down
Traffic may remain disrupted when the N7K-M132XP-12 module on the primary vpc device goes down.
Symptom | Possible Cause | Solution |
---|---|---|
Traffic disrupted when the primary vPC device goes down. |
All core facing interfaces and vPC peer-links are configured on a single N7K-M132XP-12 module. |
Enable object tracking. With object tracking enabled, all vPC on the primary will shut down. The vPC secondary will take over as the operational primary and all the vPC on the secondary will stay up. As a result, traffic will still be flowing thru the secondary which became operational primary. |
See Also
Further Reading
The following links contain further information on this topic from Cisco.com:
Configuring vPCs (Cisco Nexus 7000 Series Interfaces Configuration Guide)
Nexus 5000 Virtual PortChannel Quick Configuration Guide
External Links
The following links contain content developed by external authors. Cisco does not review this content for accuracy.
Our Nexus Data Center Network - To vPC or not to vPC
Nexus 7000 Virtual Portchannel Part 1
Nexus 7000 Virtual Portchannel Part 2
Nexus 7000 Virtual Portchannel Part 3