Cisco MDS SanOS Troubleshooting Guide -- Troubleshooting Installs, Upgrades, and Reboots
From DocWiki
This section describes how to identify and resolve problems that might occur when installing, upgrading, or restarting Cisco MDS 9000 Family products.
Generating a PDF of this section
Cisco MDS SanOS Troubleshooting Guide -- Troubleshooting Installs, Upgrades, and Reboots PDF
Overview
Each Cisco MDS 9000 switch ships with an operating system (Cisco SAN-OS) that consists of two images; the kickstart image and the system image. There is also a module image if the Storage Services Module (SSM) is present.
Installations, upgrades, and reboots are ongoing parts of SAN maintenance activities. It is important to minimize the risk of disrupting ongoing operations when performing these operations in production environments and to know how to recover quickly when something does go wrong.
![]() | Note: | For documentation purposes, we use the term upgrade in this document. The term upgrade refers to both upgrading and downgrading your switch, pertaining to the context. |
Guidelines
This section lists general guidelines for performing Cisco SAN-OS software installations, image upgrade and downgrade procedures, and reboots.
Guidelines for Installations
Follow these guidelines when installing Cisco SAN-OS software images:
- Ensure that an FTP or TFTP server is available and can be accessed via the IP address of the default gateway (rather than any other IP address on the defined subnet).
- Use the show install all impact CLI command to verify that the new image is healthy and the impact that new load will have on any hardware with regards to compatibility. Check for compatibility.
- Choose Admin > Show Image Version in the Device Manager to view information on images in the directories of the MDS file system.
Guidelines for Upgrading
Not all images need to be updated during an upgrade. Use the following checklist to prepare for an upgrade:
Checklist |
Check off |
---|---|
Copy the new Cisco SAN-OS image onto your supervisor modules in bootflash: or slot0:. |
|
Save your running configuration to the startup configuration. |
|
Back up a copy of your configuration to a remote TFTP server. |
|
Schedule your upgrade during an appropriate maintenance window for your fabric. |
|
Verify that you have the correct image for your supervisor module type. |
|
Verify that no SSM ports are configured in auto mode. |
After you have completed the checklist, you are ready to upgrade the switches in your fabric.
![]() | Note: | It is normal for the active supervisor to become the standby supervisor during an upgrade. |
Follow these guidelines when upgrading or downgrading Cisco SAN-OS software images:
- Read the Cisco SAN-OS Release Notes for the release you are upgrading or downgrading to. Cisco SAN-OS Release Notes are available at the following website: http://cisco.com/en/US/products/ps5989/prod_release_notes_list.html
- Ensure that an FTP or TFTP server is available.
- Copy the startup-config to a snapshot config in NVRAM. This step creates a backup copy of the startup-config.
- In Device Manager, choose Admin > Copy Configuration and select the startupConfig radio button for the From: field and the serverFile radio button for the To: field. Set the other fields, and click Apply.
- From the CLI, use the copy nvram:startup-config nvram-snapshot-config command.
- Where possible, choose to do a nondisruptive upgrade. In general, you can nondisruptively upgrade to Cisco SAN-OS Release 3.x software from any Cisco SAN-OS software Release 2.x or later.
- Review the upgrade table in the Cisco SAN-OS Release Notes for the version you will be installing.
- Use the show install all impact upgrade-image CLI command to determine if your upgrade will be nondisruptive.
- Establish a PC serial connection to each supervisor console to record upgrade activity to a file. This serial connection catches any error messages or problems during bootup.
- In Fabric Manager, choose Tools > Other > Software Install or click the Software Install icon on the toolbar to use the Software Install Wizard.
- From the CLI, use the install all [{asm-sfn | kickstart | ssi | system} URL] command to run a complete script, test the images, and verify the compatibility with the hardware. See the "Installing Cisco SAN-OS Software from the CLI" section. Using the install all command offers the following advantages:
- You can upgrade the entire switch using the least disruptive procedure with just one command.
- You can receive descriptive information on the intended changes to your system before you continue with the command.
- You have the option to cancel the command. Once the results of the command are shown, you can continue or cancel when you see this question (the default is no):
Do you want to continue (y/n) [n] :y
- You can view the progress of this command on the console, Telnet, and SSH screens.
- The image integrity is automatically checked, including the running kickstart and system images.
- The command performs a platform validity check to verify that a wrong image is not used. For example, the command verifies that an MDS 9500 Series image is not used inadvertently to upgrade an MDS 9200 Series switch.
- After entering the install all command, if any step in the sequence fails, the command completes the step in progress and ends. For example, if a switching module fails to be updated for any reason (for example, due to an unstable fabric state), then the command sequence disruptively updates that module and ends. In such cases, you can verify the problem on the affected switching module and upgrade the other switching modules.
- If you run the setup script after entering a write erase CLI command, you must set the default zone policy for VSAN 1 after the setup script completes. In Fabric Manager, choose Fabricxx > VSAN 1 > Default Zone, select the Policies tab and set the Default Zone Behavior drop-down menu to permit or deny. In the CLI, use the zone default-zone command.
Guidelines for Reboots
Cisco SAN-OS allows for three different types of system restarts:
- Recoverable — A process restarts and service is not affected.
- Unrecoverable — A process has restarted more than the maximum restart times within a fixed period of time (seconds) and will not be restarted again.
- System hung/crashed — No communications of any kind is possible with the system.
Schedule the reboot to avoid possible disruption of services during critical business hours.
Disruptive Module Upgrades
Software upgrades for the SSM, MPS-14/2, MSM-18/4 module, or the IP Storage (IPS) services modules are disruptive. These modules use a rolling upgrade install mechanism where the modules are upgraded in sequence. After the first module upgrade finishes, and before the next module upgrade begins, Cisco SAN-OS introduces a time delay to ensure that all applications in the module reach a steady state. The IPS modules require a five-minute delay before the next IPS module upgrade can guarantee a stable state.
SSM supports nondisruptive upgrades for the Layer 1 and Layer 2 protocols under the following conditions:
- SSM is running Cisco SAN-OS Release 2.1(2) or later and upgrading to a later release.
- The SSM hardware has the ELPD image for Release 2.1(2) installed. Use the show version module module number epld CLI command, and verify that the epld version is 0x07 or later.
- You have turned off all Layer 3 services on the SSM by deprovisioning the DPPs for Layer 3 service.
Troubleshooting a Nondisruptive Upgrade on a Fabric Switch
When a nondisruptive upgrade begins, the system notifies all services that an upgrade is about to start, and finds out whether or not the upgrade can proceed. If a service cannot allow the upgrade to proceed at this time (for example, FSPF timers are not configured to the default value, or a CFS operation is in progress), then the service will abort the upgrade. If this occurs, you will be prompted to enter the show install all failure-reason command to determine the reason why the upgrade cannot proceed.
... Do you want to continue with the installation (y/n)? [n] y Install is in progress, please wait. Notifying services about the upgrade. [# ] 0% -- FAIL. Return code 0x401E0066 (request timed out). Please issue "show install all failure-reason" to find the cause of the failure.<---system prompt to enter the show all failure-reason command. Install has failed. Return code 0x401E0066 (request timed out). Please identify the cause of the failure, and try 'install all' again. switch# show install all failure-reason Service: "cfs" failed to respond within the given time period. switch#
Enter show install all failure-reason to find the cause of the failure.
Troubleshooting Fabric Manager Installations
This section describes possible problems and solutions for a Fabric Manager installation failure. Fabric Manager requires that the appropriate version of Sun JAVA JRE be installed, based on the Fabric Manager release. Table 2-1 shows the recommended JRE for Fabric Manager 2.x and later releases.
Table 2-1 Fabric Manager and Recommended JRE Version
Fabric Manager Release |
Recommended JRE Version |
---|---|
2.0(1b) through 2.1(1b) |
1.4.2_05 |
2.1(2) through 3.3(1)1 |
1.5.x |
Fabric Manager and Device Manager do not operate properly with JRE 1.4.2_03 on Windows 2003.
Symptom:Fabric Manager or Device Manager will not start. Table 2-2 lists the scenarios and the solutions.
Table 2-2 Fabric Manager or Device Manager Will Not Start
Symptom |
Possible Cause |
Solution |
---|---|---|
Device Manager will not start. |
Device Manager proxied through Fabric Manager Server. |
Uncheck Proxy SNMP in the FM Server check box in the Device Manager startup dialog box, and restart Device Manager. |
Fabric Manager will not start. |
Using incorrect Fabric Manager Server. |
Verify that you are choosing the appropriate Fabric Manager Server from the FMServer pull-down menu. If you have not already done so, download Fabric Manager Server. |
Fabric Manager Server not running. |
On a Windows PC, choose Start > Control Panel > Administrative Tools > Services to verify that Fabric Manager Server and Fabric Manager database have started. The default setting for the Fabric Manager Server is that the server is automatically started when the PC is rebooted. |
|
Incompatible JRE version. |
Verify that you have the correct JRE version installed for the Fabric Manager release you installed. Refer to the release notes for the software version you installed to determine which JRE version is compatible. |
|
Improperly installed. |
If the problem remains, remove the application using the Cisco MDS 9000/Uninstall program, and then reinstall Fabric Manager. |
Verifying Cisco SAN-OS Software Installations
In Fabric Manager you can watch the progress of your software installation using the Software Install Wizard. From the CLI, you can use the show install all status command to watch the progress of your software installation.
You can also use the show install all status CLI command to view the on-going install all command or the log of the last installed install all command from a console, SSH, or Telnet session.
This command presents the install all output on both the active and standby supervisor module even if you are not connected to the console terminal. It only displays the status of an install all command that is issued from the CLI (not the GUI). See the following example:
switch# show install all status There is an on-going installation... <---------------------- in progress installation Enter Ctrl-C to go back to the prompt. Verifying image bootflash:/b-1.3.0.104 -- SUCCESS Verifying image bootflash:/i-1.3.0.104 -- SUCCESS Extracting "system" version from image bootflash:/i-1.3.0.104. -- SUCCESS Extracting "kickstart" version from image bootflash:/b-1.3.0.104. -- SUCCESS Extracting "loader" version from image bootflash:/b-1.3.0.104. -- SUCCESS switch# show install all status This is the log of last installation. <----------------- log of last install Verifying image bootflash:/b-1.3.0.104 -- SUCCESS Verifying image bootflash:/i-1.3.0.104 -- SUCCESS Extracting "system" version from image bootflash:/i-1.3.0.104. -- SUCCESS Extracting "kickstart" version from image bootflash:/b-1.3.0.104. -- SUCCESS Extracting "loader" version from image bootflash:/b-1.3.0.104. -- SUCCESS
Troubleshooting Cisco SAN-OS Software Upgrades and Downgrades
This section discusses possible causes and solutions for a software installation upgrade or downgrade failure.
Software Installation Reports an Incompatibility
This table describes the scenario and the solutions.
Symptom |
Possible Cause |
Solution |
---|---|---|
The software installation reports an incompatibility. |
The running image may have a feature enabled that is not compatible with the proposed new image. |
Review the incompatibility issues displayed by either the Fabric Manager Software Install Wizard or the install all CLI command. Correct any problems and retry the installation. See the "Diagnosing Compatibility Issues" section. |
Verify which features are enabled on your switch and disable any features that may not be compatible with your new image. Refer to the appropriate release notes for both images. |
Diagnosing Compatibility Issues
To view the results of a dynamic compatibility check, use the show incompatibility system bootflash:filename CLI command. Use the show incompatibility CLI command for diagnosis when the install all CLI command warns of compatibility issues. During an attempted upgrade, the install all CLI command may return the following warning:
Warning: The startup config contains commands not supported by the system image; as a result, some resources might become unavailable after an install.
Do you wish to continue? (y/ n) [y]: '''n'''
Use the show incompatibility CLI command to identify the problem.
Message 1 indicates that the remote SPAN (RSPAN) feature is in use, but it is not supported by the image that was installed. The incompatibility is strict because continuing the upgrade might cause the switch to move into an inconsistent state; that is, configured features might stop working.
switch# show incompatibility system bootflash:new-image
The following configurations on active are incompatible with the system image
1) Feature Index : 67 , Capability : CAP_FEATURE_SPAN_FC_TUNNEL_CFG
Description : SPAN - Remote SPAN feature using fc-tunnels
Capability requirement : STRICT
Message 2 indicates that the Fibre Channel tunnel feature is not supported in the new image. The RSPAN feature uses Fibre Channel tunnels.
2) Feature Index : 119 , Capability : CAP_FEATURE_FC_TUNNEL_CFG
Description : fc-tunnel is enabled
Capability requirement : STRICT
Software Installation Ends with Error
Symptom The software installation ends with an error. This table describes the scenarios and the solutions.
Problem |
Possible Cause |
Solution |
---|---|---|
The installation ends with an error. |
The standby supervisor module bootflash: file system does not have sufficient space to accept the updated image. |
Remove unnecessary files from the filesystem. In Device Manager, choose Admin > Flash Files and delete unnecessary files. From the CLI, use the delete command. |
The specified system and kickstart images are not compatible. |
Check the output of the installation process for details on the incompatibility. Possibly update the kickstart image before updating the system image. |
|
The install all command is issued on the standby supervisor module. |
Enter the command on the active supervisor module only. |
|
A module was inserted while the upgrade was in progress. |
Restart the installation. See the "Installing SAN-OS Software Using Fabric Manager" section or the "Installing Cisco SAN-OS Software from the CLI" section. |
|
The fabric or switch was configured while the upgrade was in progress. |
Wait until the upgrade is complete before configuring the switch. In Device Manager, choose Admin > CFS or from the CLI, use the show cfs lock command to check that there are no CFS commit operations in progress. |
|
The switch experienced a power disruption while the upgrade was in progress. |
Restart the installation. See the "Installing SAN-OS Software Using Fabric Manager" section or the "Installing Cisco SAN-OS Software from the CLI" section. |
|
Incorrect software image path specified. |
Specify the entire path for the remote location accurately. |
|
Another installation is already in progress. |
Verify the state of the switch at every stage and restart the installation after 10 seconds. If you restart the installation within the 10-second span, the command is rejected with an error message indicating that an installation is currently in progress. |
|
Module failed to upgrade. |
Restart the installation. See the "Installing SAN-OS Software Using Fabric Manager" section or the "Installing Cisco SAN-OS Software from the CLI" section. Or, use the install module CLI command to upgrade the failed module. |
Installing SAN-OS Software Using Fabric Manager
To use the Software Install Wizard to install a new software image using Fabric Manager, follow these steps:
1. Open the Software Install Wizard by clicking its icon in the toolbar (see Figure 2-1).
Figure 2-1 Software Install Wizard Icon
2. Select the switches you want to install images on. You must select at least one switch in order to proceed. Click Next.
3. Optional, check the Skip Image Download check box and click Next to use images that are already downloaded (the file is already on the bootflash: file system). Proceed to Step 7.
4. Click the row under the System, Kickstart, Asm-sfn, or ssi columns to enter image URIs.You must specify at least one image for each switch to proceed.
5. Check the active (and standby, if applicable) bootflash: file system on each switch to see if there is enough space for the new images. You can see this information in the Flash Space column.
6. Click Next. You see the Select Download Image screen.
7. Double-click the table cell under System, Kickstart, Asm-sfn, or Ssi and select from a drop-down list of images available in the bootflash: file system on each switch. You must select at least one image for each switch to proceed.
8. Click Next. You see the final verification screen.
9. Click Finish to start the installation or click Cancel to leave the installation wizard without installing new images.
Installing Cisco SAN-OS Software from the CLI
To perform an automated software upgrade on any switch from the CLI, follow these steps:
- Log into the switch through the console, Telnet, or SSH port of the active supervisor.
- Create a backup of your existing configuration file, if required.
- Perform the upgrade by issuing the install all command.
The example that follows demonstrates upgrading from SAN-OS 2.0(2b) to 2.1(1a) using the install all command with the source images located on a SCP server.
ca-9506# install all system scp://testuser@dino/tftpboot/rel/qa/2_1_1a/final/m95
00-sf1ek9-mz.2.1.1a.bin kickstart scp://testuser@dino/tftpboot/rel/qa/2_1_1a/fin
al/m9500-sf1ek9-kickstart-mz.2.1.1a.bin
For scp://testuser@dino, please enter password:
For scp://testuser@dino, please enter password:
Copying image from scp://testuser@dino/tftpboot/rel/qa/2_1_1a/final/m9500-sf1ek9
-kickstart-mz.2.1.1a.bin to bootflash:///m9500-sf1ek9-kickstart-mz.2.1.1a.bin.
[####################] 100% -- SUCCESS
Copying image from scp://testuser@dino/tftpboot/rel/qa/2_1_1a/final/m9500-sf1ek9
-mz.2.1.1a.bin to bootflash:///m9500-sf1ek9-mz.2.1.1a.bin.
[####################] 100% -- SUCCESS
Verifying image bootflash:///m9500-sf1ek9-kickstart-mz.2.1.1a.bin
[####################] 100% -- SUCCESS
Verifying image bootflash:///m9500-sf1ek9-mz.2.1.1a.bin
[####################] 100% -- SUCCESS
Extracting "slc" version from image bootflash:///m9500-sf1ek9-mz.2.1.1a.bin.
[####################] 100% -- SUCCESS
Extracting "ips" version from image bootflash:///m9500-sf1ek9-mz.2.1.1a.bin.
[####################] 100% -- SUCCESS
Extracting "svclc" version from image bootflash:///m9500-sf1ek9-mz.2.1.1a.bin.
[####################] 100% -- SUCCESS
Extracting "system" version from image bootflash:///m9500-sf1ek9-mz.2.1.1a.bin.
[####################] 100% -- SUCCESS
Extracting "kickstart" version from image bootflash:///m9500-sf1ek9-kickstart-mz
.2.1.1a.bin.
[####################] 100% -- SUCCESS
Extracting "loader" version from image bootflash:///m9500-sf1ek9-kickstart-mz.2.
1.1a.bin.
[####################] 100% -- SUCCESS
Compatibility check is done:
Module bootable Impact Install-type Reason
------ -------- -------------- ------------ ------
1 yes non-disruptive rolling
2 yes non-disruptive rolling
3 yes disruptive rolling Hitless upgrade is not supported
4 yes disruptive rolling Hitless upgrade is not supported
5 yes non-disruptive reset
6 yes non-disruptive reset
Images will be upgraded according to following table:
Module Image Running-Version New-Version Upg-Required
------ ---------- -------------------- -------------------- ------------
1 slc 2.0(2b) 2.1(1a) yes
1 bios v1.1.0(10/24/03) v1.1.0(10/24/03) no
2 slc 2.0(2b) 2.1(1a) yes
2 bios v1.1.0(10/24/03) v1.1.0(10/24/03) no
3 ips 2.0(2b) 2.1(1a) yes
3 bios v1.1.0(10/24/03) v1.1.0(10/24/03) no
4 svclc 2.0(2b) 2.1(1a) yes
4 svcsb 1.3(5m) 1.3(5m) no
4 svcsb 1.3(5m) 1.3(5m) no
4 bios v1.1.0(10/24/03) v1.1.0(10/24/03) no
5 system 2.0(2b) 2.1(1a) yes
5 kickstart 2.0(2b) 2.1(1a) yes
5 bios v1.1.0(10/24/03) v1.1.0(10/24/03) no
5 loader 1.2(2) 1.2(2) no
6 system 2.0(2b) 2.1(1a) yes
6 kickstart 2.0(2b) 2.1(1a) yes
6 bios v1.1.0(10/24/03) v1.1.0(10/24/03) no
6 loader 1.2(2) 1.2(2) no
Do you want to continue with the installation (y/n)? [n] y
Install is in progress, please wait.
Syncing image bootflash:///m9500-sf1ek9-kickstart-mz.2.1.1a.bin to standby.
[####################] 100% -- SUCCESS
Syncing image bootflash:///m9500-sf1ek9-mz.2.1.1a.bin to standby.
[####################] 100% -- SUCCESS
Setting boot variables.
[####################] 100% -- SUCCESS
Performing configuration copy.
[####################] 100% -- SUCCESS
Module 5: Waiting for module online.
2005 May 20 15:46:03 ca-9506 %KERN-2-SYSTEM_MSG: mts: HA communication with standby terminated. Please check the standby supervisor.
-- SUCCESS
"Switching over onto standby".
Step 4 Exit the switch console and open a new terminal session to view the upgraded supervisor module using the show module command.
If the configuration meets all guidelines when the install all command is entered, all modules (supervisor and switching) are upgraded.
Troubleshooting Cisco SAN-OS Software System Reboots
This section lists possible problems and solutions for software reboots.
Power On or Switch Reboot Hangs
Symptom Power on or switch reboot hangs.This table describes the scenarios and solutions.
Problem |
Possible Cause |
Solution |
---|---|---|
Power on or switch reboot hangs for dual supervisor configuration. |
The bootflash is corrupted. |
See the "Recovery for Switches with Dual Supervisor Modules" section. |
Power on or switch reboot hangs for single supervisor configuration. |
The loader is corrupted. |
Interrupt the boot process and reconfigure the BIOS through the console port to load a new kickstart image that updates to BIOS image. See the "Recovery Using BIOS Setup for Supervisor-1" section. |
The BIOS is corrupted. |
Replace this module. Contact your customer support representative to return the failed module. |
|
The kickstart image is corrupted. |
Interrupt the boot process at the >loader prompt. Update the kickstart image. See the "Recovery from the loader > Prompt on Supervisor-2 Modules" section. |
|
Boot parameters are incorrect. |
Verify and correct the boot parameters and reboot. |
|
The system image is corrupted. |
Interrupt the boot process at the switch#boot prompt. Update the system image. See the "Recovery from the switch(boot)# Prompt" section. |
Corrupted Bootflash Recovery
All switch configurations reside in the internal bootflash. If you have a corrupted internal bootflash you could potentially lose your configuration. Be sure to save and back up your configuration files periodically. The regular switch boot goes through the following sequence:
- The basic input/output system (BIOS) loads the loader.
- The loader loads the kickstart image into RAM and starts the kickstart image.
- The kickstart image loads and starts the system image.
- The system image reads the startup configuration file.
Figure 2-2 Regular Boot Sequence
If the images on your switch are corrupted and you cannot proceed (error state), you can interrupt the switch boot sequence and recover the image by entering the BIOS configuration utility described in the following section. Access this utility only when needed to recover a corrupted internal disk.
![]() | Note: | The BIOS changes explained in this section are required only to recover a corrupted bootflash. |
Recovery procedures require the regular sequence to be interrupted. The internal switch sequence goes through four phases between the time you turn on the switch and the time the switch prompt appears on your terminal—BIOS, boot loader, kickstart, and system. Table 2-6 provides more information.
Phase |
Normal Prompt1 |
Recovery Prompt2 |
Description |
---|---|---|---|
BIOS |
loader> |
No bootable device |
The BIOS begins the power-on self test, memory test, and other operating system applications. While the test is in progress, press Ctrl-C to enter the BIOS configuration utility and use the netboot option. |
Boot loader |
Starting kickstart |
loader> |
The boot loader uncompresses loaded software to boot an image using its file name as reference. These images are made available through bootflash. When the memory test is over, press Esc to enter the boot loader prompt. |
Kickstart |
Uncompressing system |
switch(boot)# |
When the boot loader phase is over, press Ctrl-]3 (Control key plus right bracket key) to enter the switch(boot)# prompt. If the corruption causes the console to stop at this prompt, copy the system image and reboot the switch. |
System |
Login: |
— |
The system image loads the configuration file of the last saved running configuration and returns a switch login prompt. |
|
Figure 2-3 Regular and Recovery Sequence
Recovery Using BIOS Setup for Supervisor-1
![]() | Note: | Supervisor-2 modules do not provide access to the BIOS. |
![]() | Caution: | This procedure uses the init system command, which reformats the file system of the device. Be sure that you have made a backup of the configuration files before you begin this procedure. |
To recover a corrupted bootflash: device (no bootable device found message) for a switch with a single supervisor-1 module, follow these steps:
1. Connect to the console port of the required switch.
2. Boot or reboot the switch.
3. Press Ctrl-C to interrupt the BIOS setup during the BIOS memory test.
Figure 2-4 BIOS Setup Utility
4. Press the Tab key to select the Basic CMOS Configuration.
Figure 2-5 BIOS Setup Configuration (CMOS)
5. Change the Boot 1st: field to TFTP.
6. Press the Tab key until you reach the Local IP Address field.
7. Enter the local IP address for the switch, and press the Tab key.
8. Enter the subnet mask for the IP address, and press the Tab key.
9. Enter the IP address of the default gateway, and press the Tab key.
10. Enter the IP address of the TFTP server, and press the Tab key.
11. Enter the image name (kickstart), and press the Tab key. Use the full directory path from the TFTP server root directory.
Figure 2-6 BIOS Setup Configuration (CMOS) Changes
12. Press the Esc key to return to the main menu.
13. Choose Write to CMOS and Exit from the main screen to save your changes. You see the following prompt: switch(boot)#.
14. Enter the init system command at the switch(boot)# prompt, and press Enter to reformat the file system.
15. Enter switch(boot)# init system.
16. Follow the procedure specified in the "Recovery from the switch(boot)# Prompt" section.
![]() | Note: | Your navigating options are provided at the bottom of the screen: |
* Tab = Jump to next field
* Ctrl-E = Down arrow
* Ctrl-X = Up arrow
* Ctrl-H = Erase.Backspace might not work if your terminal is not configured properly.
![]() | Caution: | The switch must have IP connectivity to reboot using the newly configured values. |
![]() | Note: | The init system command also installs a new loader from the existing (running) kickstart image. |
![]() | Caution: | Be sure that you have made a backup of the configuration files before you issue this command. |
Recovery from the loader> Prompt on Supervisor-2 Modules
![]() | Caution: | This procedure uses the init system command, which reformats the file system of the device. Be sure that you have made a backup of the configuration files before you begin this procedure. |
The loader> prompt is different from the regular switch# prompt.
- The CLI command completion feature does not work at this prompt and may result in undesired errors. You must type the command exactly as you want the command to appear.
- The ICMP stack is not supported, so you cannot ping the TFTP server.
- The TFTP server must be configured with the IP address of the default gateway (rather than any other IP address on the defined subnet.
![]() | Note: | Use the help command at the loader> prompt to display a list of commands available at this prompt or to obtain more information about a specific command in that list. |
To recover a corrupted kickstart image (system error state) for a switch with a single supervisor module, follow these steps:
1. Enter the local IP address for the switch at the loader> prompt, and press Enter.
loader> net --ip=172.16.1.2
2. Specify the subnet mask.
loader> net --nm= 255.255.255.0
3. Specify the IP address of the default gateway.
loader> net --gw=172.16.1.1
4. Boot the kickstart image file from the required server.
loader> boot tftp://172.16.10.100/m9500-kickstart-3.0.bin
In this example, 172.16.10.100 is the IP address of the TFTP server, and m9500-kickstart-3.0.bin is the name of the kickstart image file that exists on that server.The switch(boot)# prompt indicates that you have a usable kickstart image.
5. Issue the init system command at the switch(boot)# prompt.
switch(boot)# init system
![]() | Caution: | Be sure that you have made a backup of the configuration files before you issue this command. |
6. Follow the procedure specified in the "Recovery from the switch(boot)# Prompt" section.
Recovery from the loader> Prompt on Supervisor-1 Modules
![]() | Caution: | This procedure uses the init system command, which reformats the file system of the device. Be sure that you have made a backup of the configuration files before you begin this procedure. |
The loader> prompt is different from the regular switch# prompt.
- The CLI command completion feature does not work at this prompt and may result in undesired errors. You must type the command exactly as you want the command to appear.
- The ICMP stack is not supported, so you cannot ping the TFTP server.
- The TFTP server must be configured with the IP address of the default gateway (rather than any other IP address on the defined subnet.
![]() | Note: | Use the help command at the loader> prompt to display a list of commands available at this prompt or to obtain more information about a specific command in that list. |
To recover a corrupted kickstart image (system error state) for a switch with a single supervisor module, follow these steps:
1. Enter the local IP address and the subnet mask for the switch at the loader> prompt, and press Enter.
loader> ip address 172.16.1.2 255.255.255.0
Found Intel EtherExpressPro100 82559ER at 0xe800, ROM address 0xc000
Probing...[Intel EtherExpressPro100 82559ER]Ethernet addr: 00:05:30:00:52:27
Address: 172.16.1.2
Netmask: 255.255.255.0
Server: 0.0.0.0
Gateway: 0.0.0.0
2. Specify the IP address of the default gateway.
loader> ip default-gateway 172.16.1.1
Address: 172.16.1.2
Netmask: 255.255.255.0
Server: 0.0.0.0
Gateway: 172.16.1.1
3. Boot the kickstart image file from the required server.
loader> boot tftp://172.16.10.100/kickstart-image1
Address: 172.16.1.2
Netmask: 255.255.255.0
Server: 172.16.10.100
Gateway: 172.16.1.1
Booting: /kick-282 console=ttyS0,9600n8nn quiet loader_ver= "2.1(2)"....
............................................Image verification OK
Starting kernel...
INIT: version 2.78 booting
Checking all filesystems..... done.
Loading system software
INIT: Sending processes the TERM signal
Sending all processes the TERM signal... done.
Sending all processes the KILL signal... done.
Entering single-user mode...
INIT: Going single user
INIT: Sending processes the TERM signal
switch(boot)#
The switch(boot)# prompt indicates that you have a usable Kickstart image.
4. Issue the init system command at the switch(boot)# prompt.
switch(boot)# init system
![]() | Caution: | Be sure that you have made a backup of the configuration files before you issue this command. |
5. Follow the procedure specified in the "Recovery from the switch(boot)# Prompt" section.
Recovery from the switch(boot)# Prompt
To recover a system image using the kickstart image for a switch with a single supervisor module, follow these steps:
1. Change to configuration mode.
switch(boot)#config t
switch(boot)(config)#
2. Follow this step if you entered the init system command. Otherwise, skip to next step.
a. Enter the ip default-gateway command to configure the IP address of the default gateway.
switch(boot)(config)#ip default-gateway 209.165.200.226
b. Configure the IP address of the mgmt0 interface.
switch(boot)(config)#interface mgmt 0
switch(boot)(config-if)#ip address 209.165.200.227 255.255.255.0
3. Enter the no shutdown command to enable the mgmt0 interface on the switch.
switch(boot)(config-mgmt0)# no shutdown
4. Enter end to exit to EXEC mode.
switch(boot)(config-mgmt0)# end
5. If you believe there are file system problems, issue the init system check-filesystem command. As of Cisco MDS SAN-OS Release 2.1(1a), this command checks all internal file systems and fixes any errors that are encountered. This command takes considerable time to complete.
switch(boot)# init system check-filesytem
6. Copy the system image from the required TFTP server.
switch(boot)# copy tftp://172.16.10.100/system-image1 bootflash:system-image1
7. Copy the kickstart image from the required TFTP server.
switch(boot)# copy tftp://172.16.10.100/kickstart-image1 bootflash:kickstart-image1
8. Verify that the system and kickstart image files are copied to your bootflash: file system.
switch(boot)# dir bootflash:
46080 Nov 11 21:48:55 2008 lost+found/
14753280 Nov 11 21:39:49 2008 kickstart-image1
78473925 Nov 11 21:37:12 2008 system-image1
Usage for bootflash://sup-local
107465728 bytes used
78619648 bytes free
186085376 bytes total
9. Load the system image from the bootflash: files system.
switch(boot)# load bootflash:system-image1
Uncompressing system image: bootflash:/system-image1
CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC
Would you like to enter the initial configuration mode? (yes/no): yes
![]() | Note: | If you enter no, you will return to the switch# login prompt, and you must manually configure the switch. |
10. Log in to the switch using the password configured in Step 9.
switch login:admin
Password:
Cisco Storage Area Networking Operating System (SAN-OS) Software
TAC support: http://www.cisco.com/tac
Copyright (c) 2002-2008, Cisco Systems, Inc. All rights reserved.
The copyrights to certain works contained herein are owned by
other third parties and are used and distributed under license.
Some parts of this software may be covered under the GNU Public
License or the GNU Lesser General Public License. A copy of
each such license is available at
http://www.gnu.org/licenses/gpl.html and
http://www.gnu.org/licenses/lgpl.html
switch#
11. Configure the boot variable.
switch #config t
switch(config)#boot kickstart bootflash:kickstart-image1
switch(config)#boot system bootflash:system-image1
switch(config)#end
switch#
12. Save the configuration.
switch# copy running-config startup-config
[########################################] 100%
switch#
Recovery for Switches with Dual Supervisor Modules
This section describes how to recover when one or both supervisor modules in a dual supervisor switch have corrupted bootflash.
Recovering One Supervisor Module with Corrupted Bootflash
If one supervisor module has functioning bootflash and the other has corrupted bootflash, follow these steps:
1. Boot the functioning supervisor module and log on to the switch.
2. At the switch# prompt on the booted supervisor module, issue the reload module slot force-dnld command, where slot is the slot number of the supervisor module with the corrupted bootflash.
The supervisor module with the corrupted bootflash performs a netboot and checks the bootflash for corruption. When the bootup scripts discover that the bootflash is corrupted, it generates an init system command, which fixes the corrupt bootflash. The supervisor boots as the HA standby.
Recovering Both Supervisor Modules With Corrupted Bootflash
If both supervisor modules have corrupted bootflash, follow these steps:
1. Boot the switch and press the Esc key after the BIOS memory test to interrupt the boot loader.
- Press Esc immediately after you see the following message:
00000589K Low Memory Passed
00000000K Ext Memory Passed
Hit ^C if you want to run SETUP....
Wait.....
If you wait too long, you will skip the boot loader phase and enter the kickstart phase.
You see the loader> prompt.
![]() | Note: | Use the help command at the loader> prompt to display a list of commands available at this prompt or to obtain more information about a specific command in that list. |
2. Specify the local IP address and the subnet mask for the switch.
loader> ip address 172.16.1.2 255.255.255.0
Found Intel EtherExpressPro100 82559ER at 0xe800, ROM address 0xc000
Probing...[Intel EtherExpressPro100 82559ER]Ethernet addr: 00:05:30:00:52:27
Address: 172.16.1.2
Netmask: 255.255.255.0
Server: 0.0.0.0
Gateway: 0.0.0.0
3. Specify the IP address of the default gateway.
loader> ip default-gateway 172.16.1.1
Address: 172.16.1.2
Netmask: 255.255.255.0
Server: 0.0.0.0
Gateway: 172.16.1.1
4. Boot the kickstart image file from the required server.
loader> boot tftp://172.16.10.100/kickstart-latest
Address: 172.16.1.2
Netmask: 255.255.255.0
Server: 172.16.10.100
Gateway: 172.16.1.1
Booting: /kick-282 console=ttyS0,9600n8nn quiet loader_ver= "2.1(2)"....
............................................Image verification OK
Starting kernel...
INIT: version 2.78 booting
Checking all filesystems..... done.
Loading system software
INIT: Sending processes the TERM signal
Sending all processes the TERM signal... done.
Sending all processes the KILL signal... done.
Entering single-user mode...
INIT: Going single user
INIT: Sending processes the TERM signal
switch(boot)#
The switch(boot)# prompt indicates that you have a usable Kickstart image.
- Issue the init-system command to repartition and format the bootflash.
- Perform the procedure specified in the "Recovery from the switch(boot)# Prompt" section.
- Perform the procedure specified in the "Recovering One Supervisor Module With Corrupted Bootflash" section to recover the other supervisor module.
Recognizing Error States
If you see one or both of the error messages displayed in Figure 2-7 or Figure 2-8, follow the procedure specified in the "Recovery Using BIOS Setup for Supervisor-1" section.
Figure 2-7 Error State if Powered On and Ctrl-C Is Entered
Figure 2-8 Error State if Powered On and Esc Is Pressed
Switch or Process Resets
When a recoverable or nonrecoverable error occurs, the switch or a process on the switch may reset.
Symptom The switch or a process on the switch reset. See the table below for the scenarios and solution:
Problem |
Possible Cause |
Solution |
---|---|---|
The switch or a process on the switch resets. |
A recoverable error occurred on the system or on a process in the system. |
Cisco SAN-OS automatically recovered from the problem. See the "Recoverable System Restarts" section and the "Switch or Process Resets" section. |
A nonrecoverable error occurred on the system. |
Cisco SAN-OS cannot recover automatically from the problem. See the "Unrecoverable System Restarts" section to determine the cause. |
|
A clock module failed. |
Verify that a clock module failed. See the "Troubleshooting Clock Module Issues" section on page 4-12. Replace the failed clock module during the next maintenance window. |
Recoverable System Restarts
Every process restart generates a syslog message and a Call Home event. Even if the event does not affect service, you should identify and resolve the condition immediately because future occurrences could cause service interruption.
To respond to a recoverable system restart, follow these steps:
- Enter the following command to check the syslog file to see which process restarted and why it restarted:
</p>
switch# show log logfile | include error
For information about the meaning of each message, refer to the Cisco MDS 9000 Family System Messages Reference.
The system output looks like the following example:
Sep 10 23:31:31 dot-6 % LOG_SYSMGR-3-SERVICE_TERMINATED: Service "sensor" (PID 704) has finished with error code SYSMGR_EXITCODE_SY.
switch# show logging logfile | include fail
Jan 27 04:08:42 88 %LOG_DAEMON-3-SYSTEM_MSG: bind() fd 4, family 2, port 123, ad
dr 0.0.0.0, in_classd=0 flags=1 fails: Address already in use
Jan 27 04:08:42 88 %LOG_DAEMON-3-SYSTEM_MSG: bind() fd 4, family 2, port 123, ad
dr 127.0.0.1, in_classd=0 flags=0 fails: Address already in use
Jan 27 04:08:42 88 %LOG_DAEMON-3-SYSTEM_MSG: bind() fd 4, family 2, port 123, ad
dr 127.1.1.1, in_classd=0 flags=1 fails: Address already in use
Jan 27 04:08:42 88 %LOG_DAEMON-3-SYSTEM_MSG: bind() fd 4, family 2, port 123, ad
dr 172.22.93.88, in_classd=0 flags=1 fails: Address already in use
Jan 27 23:18:59 88 % LOG_PORT-5-IF_DOWN: Interface fc1/13 is down (Link failure
or not-connected)
Jan 27 23:18:59 88 % LOG_PORT-5-IF_DOWN: Interface fc1/14 is down (Link failure
or not-connected)
Jan 28 00:55:12 88 % LOG_PORT-5-IF_DOWN: Interface fc1/1 is down (Link failure o
r not-connected)
Jan 28 00:58:06 88 % LOG_ZONE-2-ZS_MERGE_FAILED: Zone merge failure, Isolating p
ort fc1/1 (VSAN 100)
Jan 28 00:58:44 88 % LOG_ZONE-2-ZS_MERGE_FAILED: Zone merge failure, Isolating p
ort fc1/1 (VSAN 100)
Jan 28 03:26:38 88 % LOG_ZONE-2-ZS_MERGE_FAILED: Zone merge failure, Isolating p
ort fc1/1 (VSAN 100)
Jan 29 19:01:34 88 % LOG_PORT-5-IF_DOWN: Interface fc1/1 is down (Link failure o
r not-connected)
switch#
- Enter the following command to identify the processes that are running and the status of each process.
switch# show processes
The following codes are used in the system output for the State (process state):
•D = uninterruptible sleep (usually I/O)
•R = runnable (on run queue)
•S = sleeping
•T = traced or stopped
•Z = defunct ("zombie") process
•NR = notrunning
•ER = should be running but currently notrunning
![]() | Note: | ER usually is the state a process enters if it has been restarted too many times and has been detected as faulty by the system and disabled. |
The system output looks like the following example. (The output has been abbreviated to be more concise.)
PID State PC Start_cnt TTY Process
----- ----- -------- ----------- ---- -------------
1 S 2ab8e33e 1 - init
2 S 0 1 - keventd
3 S 0 1 - ksoftirqd_CPU0
4 S 0 1 - kswapd
5 S 0 1 - bdflush
6 S 0 1 - kupdated
71 S 0 1 - kjournald
136 S 0 1 - kjournald
140 S 0 1 - kjournald
431 S 2abe333e 1 - httpd
443 S 2abfd33e 1 - xinetd
446 S 2ac1e33e 1 - sysmgr
452 S 2abe91a2 1 - httpd
453 S 2abe91a2 1 - httpd
456 S 2ac73419 1 S0 vsh
469 S 2abe91a2 1 - httpd
470 S 2abe91a2 1 - httpd
- Enter the following command to show the processes that have had abnormal exits and to show if there is a stack-trace or core dump:
switch# show process log
Process PID Normal-exit Stack-trace Core Log-create-time
---------------- ------ ----------- ----------- ------- ---------------
ntp 919 N N N Jan 27 04:08
snsm 972 N Y N Jan 24 20:50
- Enter the following command to show detailed information about a specific process that has restarted:
switch# show processes log pid 898
Service: idehsd
Description: ide hotswap handler Daemon
Started at Mon Sep 16 14:56:04 2002 (390923 us)
Stopped at Thu Sep 19 14:18:42 2002 (639239 us)
Uptime: 2 days 23 hours 22 minutes 22 seconds
Start type: SRV_OPTION_RESTART_STATELESS (23)
Death reason: SYSMGR_DEATH_REASON_FAILURE_SIGTERM (3)
Exit code: signal 15 (no core)
CWD: /var/sysmgr/work
Virtual Memory:
CODE 08048000 - 0804D660
DATA 0804E660 - 0804E824
BRK 0804E9A0 - 08050000
STACK 7FFFFD10
Register Set:
EBX 00000003 ECX 0804E994 EDX 00000008
ESI 00000005 EDI 7FFFFC9C EBP 7FFFFCAC
EAX 00000008 XDS 0000002B XES 0000002B
EAX 00000003 (orig) EIP 2ABF5EF4 XCS 00000023
EFL 00000246 ESP 7FFFFC5C XSS 0000002B
Stack: 128 bytes. ESP 7FFFFC5C, TOP 7FFFFD10
0x7FFFFC5C: 0804F990 0804C416 00000003 0804E994 ................
0x7FFFFC6C: 00000008 0804BF95 2AC451E0 2AAC24A4 .........Q.*.$.*
0x7FFFFC7C: 7FFFFD14 2AC2C581 0804E6BC 7FFFFCA8 .......*........
0x7FFFFC8C: 7FFFFC94 00000003 00000001 00000003 ................
0x7FFFFC9C: 00000001 00000000 00000068 00000000 ........h.......
0x7FFFFCAC: 7FFFFCE8 2AB4F819 00000001 7FFFFD14 .......*........
0x7FFFFCBC: 7FFFFD1C 0804C470 00000000 7FFFFCE8 ....p...........
0x7FFFFCCC: 2AB4F7E9 2AAC1F00 00000001 08048A2C ...*...*....,...
PID: 898
SAP: 0
UUID: 0
switch#
- Enter the following command to determine if the restart recently occurred:
switch# show system uptime
Start Time: Fri Sep 13 12:38:39 2002
Up Time: 0 days, 1 hours, 16 minutes, 22 seconds
To determine if the restart is repetitive or a one-time occurrence, compare the length of time that the system has been up with the timestamp of each restart.
- Enter the following command to view the core files:
switch# show cores
Module-num Process-name PID Core-create-time
---------- ------------ --- ----------------
5 fspf 1524 Jan 9 03:11
6 fcc 919 Jan 9 03:09
8 acltcam 285 Jan 9 03:09
8 fib 283 Jan 9 03:08
The output shows all cores that are presently available for upload from the active supervisor. The module-num column shows the slot number on which the core was generated. In the previous example, an FSPF core was generated on the active supervisor module in slot 5. An FCC core was generated on the standby supervisory module in slot 6. Core dumps generated on the module in slot 8 include ACLTCAM and FIB.
To copy the FSPF core dump in this example to a TFTP server with the IP address 1.1.1.1, enter the following command:
switch# copy core://5/1524 tftp::/1.1.1.1/abcd
The following command displays the file named zone_server_log.889 in the log directory:
switch# show pro log pid 1473
======================================================
Service: ips
Description: IPS Manager
Started at Tue Jan 8 17:07:42 1980 (757583 us)
Stopped at Thu Jan 10 06:16:45 1980 (83451 us)
Uptime: 1 days 13 hours 9 minutes 9 seconds
Start type: SRV_OPTION_RESTART_STATELESS (23)
Death reason: SYSMGR_DEATH_REASON_FAILURE_SIGNAL (2)
Exit code: signal 6 (core dumped)
CWD: /var/sysmgr/work
Virtual Memory:
CODE 08048000 - 080FB060
DATA 080FC060 - 080FCBA8
BRK 081795C0 - 081EC000
STACK 7FFFFCF0
TOTAL 20952 KB
Register Set:
EBX 000005C1 ECX 00000006 EDX 2AD721E0
ESI 2AD701A8 EDI 08109308 EBP 7FFFF2EC
EAX 00000000 XDS 0000002B XES 0000002B
EAX 00000025 (orig) EIP 2AC8CC71 XCS 00000023
EFL 00000207 ESP 7FFFF2C0 XSS 0000002B
Stack: 2608 bytes. ESP 7FFFF2C0, TOP 7FFFFCF0
0x7FFFF2C0: 2AC8C944 000005C1 00000006 2AC735E2 D..*.........5.*
0x7FFFF2D0: 2AC8C92C 2AD721E0 2AAB76F0 00000000 ,..*.!.*.v.*....
0x7FFFF2E0: 7FFFF320 2AC8C920 2AC513F8 7FFFF42C ... ..*...*,...
0x7FFFF2F0: 2AC8E0BB 00000006 7FFFF320 00000000 ...*.... .......
0x7FFFF300: 2AC8DFF8 2AD721E0 08109308 2AC65AFC ...*.!.*.....Z.*
0x7FFFF310: 00000393 2AC6A49C 2AC621CC 2AC513F8 .......*.!.*...*
0x7FFFF320: 00000020 00000000 00000000 00000000 ...............
0x7FFFF330: 00000000 00000000 00000000 00000000 ................
0x7FFFF340: 00000000 00000000 00000000 00000000 ................
0x7FFFF350: 00000000 00000000 00000000 00000000 ................
0x7FFFF360: 00000000 00000000 00000000 00000000 ................
0x7FFFF370: 00000000 00000000 00000000 00000000 ................
0x7FFFF380: 00000000 00000000 00000000 00000000 ................
0x7FFFF390: 00000000 00000000 00000000 00000000 ................
0x7FFFF3A0: 00000002 7FFFF3F4 2AAB752D 2AC5154C .
... output abbreviated ...
Stack: 128 bytes. ESP 7FFFF830, TOP 7FFFFCD0
- Enter the following command to configure the switch to use TFTP to send the core dump to a TFTP server:
system cores tftp:[//servername][/path]
This command causes the switch to enable the automatic copy of core files to a TFTP server. For example, the following command sends the core files to the TFTP server with the IP address 10.1.1.1:
switch(config)# system cores tftp://10.1.1.1/cores
The following conditions apply:
- The core files are copied every 4 minutes. This time interval is not configurable.
- The copy of a specific core file to a TFTP server can be manually triggered, using the command copy core://module#/pid# tftp://tftp_ip_address/file_name.
- The maximum number of times a process can be restarted is part of the HA policy for any process. (This parameter is not configurable.) If the process restarts more than the maximum number of times, the older core files are overwritten.
- The maximum number of core files that can be saved for any process is part of the HA policy for any process. (This parameter is not configurable, and it is set to three.)
- Determine the cause and resolution for the restart condition by contacting your customer support representative and asking the representative to review your core dump.
See also the "Troubleshooting Supervisor Issues" section on page 4-14 or the "Troubleshooting Switching and Services Modules" section on page 4-21.
Unrecoverable System Restarts
An unrecoverable system restart might occur in the following cases:
- A critical process fails and is not restartable.
- A process restarts more times than is allowed by the system configuration.
- A process restarts more frequently than is allowed by the system configuration.
The effect of a process reset is determined by the policy configured for each process. Unrecoverable reset may cause loss of functionality, restart of the active supervisor, a supervisor switchover, or restart of the switch.
To respond to an unrecoverable reset, see the "Troubleshooting Cisco SAN-OS Software System Reboots" section.
The show system reset-reason CLI command displays the following information:
- In a Cisco MDS 9500 Series switch, the last four reset-reason codes for the supervisor module in slot 5 and slot 6 are displayed. If either supervisor module is absent, the reset-reason codes for that supervisor module are not displayed.
- In a Cisco MDS 9200 Series switch, the last four reset-reason codes for the supervisor module in slot 1 are displayed.
- The show system reset-reason module number command displays the last four reset-reason codes for a specific module in a given slot. If a module is absent, then the reset-reason codes for that module are not displayed.
- Find the overall history of when and why expected and unexpected reloads occur.
- Timestamp of when the reset or reload occurred
- Reason for the reset or reload of a module
- The service that caused the reset or reload (not always available)
- The software version that was running at the time of the reset or reload
Example:
switch# show system reset-reason module 5
----- reset reason for module 5 -----
1) At 224801 usecs after Fri Jan 21 16:36:40 2005
Reason: Reset Requested by CLI command reload
Service:
Version: 2.1(2)
2) At 922828 usecs after Fri Jan 21 16:02:48 2005
Reason: Reset Requested by CLI command reload
Service:
Version: 2.1(2)
3) At 318034 usecs after Fri Jan 21 14:03:36 2005
Reason: Reset Requested by CLI command reload
Service:
Version:2.1(2)
4) At 255842 usecs after Wed Jan 19 00:07:49 2005
Reason: Reset Requested by CLI command reload
Service:
Version: 2.1(2)
Recovering the Administrator Password
You can access the switch if you forget the administrator password by following the directions in the below table. Symptom You forgot the administrator password for accessing a switch.
Problem |
Solution |
---|---|
You forgot the administrator password for accessing a Cisco MDS 9000 Family switch. |
You can recover the password using a local console connection. For the latest instructions on password recovery, refer to the Cisco MDS 9000 CLI Family Configuration Guide at the following website: http://cisco.com/en/US/products/ps5989/products_installation_and_configuration_guides_list.html |
If you can access Device Manager, recover the administrator password by following these steps:
- Create a text file on the TFTP server containing the desired user name and password:
"username admin password 0 admin123"
- Click Admin > Copy Configuration to copy the file from the TFTP server to the running configuration on the switch.
![]() | Note: | The clear text password "admin123" will be copied over the existing password and encrypted in the running configuration. |
- Click Device > Command Line Interface to log into the switch and verify the new password.
- Click Admin > Save Configuration to save the running configuration to the startup configuration.
Miscellaneous Software Image Issues
This section includes software image issues reported by the relevant release notes.
All Ports Down Because of System Health Failure
Symptom Console reports all ports on a module are down because of a system health failure. See the table below for scenarios and solution:
Symptom |
Possible Cause |
Solution |
---|---|---|
The system console reports that the module's ports are down because of a system health failure. |
An incorrect process on the Cisco MDS 9000 modules might have been reinitialized from an error recovery mechanism, leaving the module in an unusable state. In some cases, the module may reboot. |
Downgrade to a Cisco SAN-OS Release 2.0(x) version supported by your OSM. |
Upgrade to Cisco SAN-OS Release 2.1.2 or 2.1(1b). Resetting the module will clear the problem, but the problem could reoccur unless you are using a SAN-OS version with the bug fix. |
Switch Reboots after FCIP Reload
Symptom Switch rebooted after FCIP module was reloaded, upgraded, or downgraded. See the table below for scenarios and solution:
Symptom |
Possible Cause |
Solution |
---|---|---|
Switch rebooted after FCIP module was reloaded, upgraded, or downgraded. |
If an IPS module with operational FCIP PortChannels is reloaded, upgraded, or downgraded, the supervisor module might reload and cause the system to reboot. |
Before reloading, upgrading, or downgrading an IPS module, shut down all FCIP PortChannels on the module. |
FCIP Link Fails to Come Up
Symptom A newly configured FCIP link may fail to come up when running on an MPS-14/2 module.See the table below for the scenarios and solution:
Symptom |
Possible Cause |
Solution |
---|---|---|
A newly configured FCIP link may fail to come up when running on an MPS-14/2 module. |
This symptom may occur following an upgrade from Cisco MDS SAN-OS Release 2.0(1b) to Release 2.0(3) and following the configuration of a new FCIP link. |
Reload the MPS-14/2 module using the reload module module-number command, where module-number is a specific module. |
Cannot Create, Modify, or Delete Admin Role
Symptom Cannot create, modify, or delete the admin role. See the table below for the scenarios and solution:
Symptom |
Possible Cause |
Solution |
---|---|---|
Cannot create, modify, or delete the admin role. |
After upgrading to Cisco SAN-OS Release 2.0, you cannot create, modify, or delete the admin role. |
Create the admin role before upgrading to Cisco SAN-OS Release 2.0. |
FC IDs Change after Link Reset
Symptom FC IDs change after a link resets.See the table below for the scenarios and solution:
Symptom |
Possible Cause |
Solution |
---|---|---|
FC IDs change after a link resets. |
Following an upgrade from Cisco SAN-OS Release 1.1 to Cisco SAN-OS Release 1.3 or later, with persistent FC ID enabled, the FC IDs for the storage arrays might change after a link flap. |
Reconfigure the FC IDs as necessary. |
Switch Displays Wrong User
Symptom Switch displays the wrong user with the show running-config CLI command.See the table below for the scenarios and solution:
Symptom |
Possible Cause |
Solution |
---|---|---|
Switch displays the wrong user with the show running-config CLI command. |
When you perform a nondisruptive upgrade from Cisco SAN-OS Release 1.3(x) to Cisco SAN-OS Release 2.0(x) and then issue the show running-config command, the switch displays the wrong user. The user shown after the nondisruptive upgrade is different from the user shown when you issue the show user-account command. |
Recreate the user. |