Cisco Automated Administrator (AAS) for Symposium: AAS - Error reports that Side B Master Selection will not start

From DocWiki

Revision as of 23:53, 12 March 2010 by Cchetty (Talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

AAS - Error reports that Side B Master Selection will not start

Problem Summary Error reports that Side B Master Selection will not start.
Error Message None
Possible Cause Incorrect configuration.
Recommended Action Check the Windows registry and ensure that the following values are not blank, null, or 0:

Base: HKEY_LOCAL_MACHINE/SOFTWARE/Cisco Systems, Inc./ICM/<ICM instance>/PG<XX>/PG/CurrentVersion/AASS/aas<X>/AASData/Config

Note: PG<XX> represents PG name. aas<X> represents AAS name.

Values: AASPGHostB, AASPGPortB


Release Release 7.5(1) and 8.0
Associated CDETS # None.

Rating: 0.0/5 (0 votes cast)