VRU Application Error in Call Server Log

Problem Summary The call might not go through the Call Server, so a prompt is not played. An error or warning message might appear in the Call Server log.
Error Message VRU APPLICATION ERROR: Assigning the tag 7 to the non-existing ECC variable “user.microapp.error_code”.
Possible Cause The ECC Variable is not configured on the Unified ICME and/or NAM software, or the defined length is not the same on both devices.
Recommended Action Add the identical ECC variable definition to the Unified ICME and/or NAM.
Release Release 7.0(2)